Operations Manual (OM700-02)

Technical Information

Planar D6015TM Series Medical Monitor Specifications

Display Panel

15-inch (381 mm) XGA active matrix LCD (AMLCD)

Display Colors

262,144

Dimensions:

w/bracket

w/desk stand

408 x 333 x 85 mm (W x H x D)
408 x 387 x 175 mm (W x H x D)

Weight:

w/bracket

w/desk stand

4.9 kg (10.8 lbs.)
6.9 kg (15.2 lbs.)

Display Area

304.1 x 228.1 mm (W x H), 15inch (381 mm) diagonal

Response:

Wht>Blk
Blk>Wht

10 ms typical
15 ms typical

Viewing Angle:

H or V

±

80 ° typ., contrast ratio >10

Contrast Ratio

300:1 typical

Brightness:

Non-touch

w/SAW

w/RT

228 cd/m

2

 typical

225 cd/m

2

 typical

200 cd/m

2

 typical

Pixel Pitch

0.297 x 0.297 mm

Reliability

40k hours MTBF, excluding backlight

Video Interface

VGA-compatible analog RGB (15-pin D-Sub), Separate
Sync. / Composite Sync.

Scanning Frequency

24-61 kHz (horizontal), 50-90 Hz (vertical)

Factory Preset Modes

25

Power Management

Meets VESA DPMS, EPA

Power Consumption

30 W on, 4.5 W standby (not including power adapter)

Net Weight

6.9 kg, 15.2 lb

Power Supply:

12V / 3A, 36W, Input power 100 Vac to 240 Vac at 50 to
60 Hz, AC Adapter (external)

Options

Desk Stand, Resistive Touchscreen, SAW Touchscreen

Temperature:

Operating

Non-operating

0 to 40 °C
-20 to 65 °C

Humidity:

Operating

Non-operating

10 to 90% RH non-condensing, per IEC 68-2-3
0 to 95% RH non-condensing, per IEC 68-2-30

Altitude

0 to 10k ft Operating, per IEC 68-2-13, 4 hr
0 to 40k ft. Non-operating, per IEC 68-2-13, 4 hr

Shock

50g, 11ms duration. Operating/Non-operating. Half sine
with 3 shocks on each of six axes per IEC 68-2-27.

Audio

Two 1-Watt speakers with amplifier

Regulatory

TÜV Safety Mark, CSA (C US Mark), CE Mark-MDD

Содержание VitalScreen D6015TM

Страница 1: ...The Definition of Quality D6015TM SERIES MEDICAL MONITOR D6015TM 15 XGA D6015TM TS 15 XGA SAW TOUCHSCREEN D6015TM TR 15 XGA RESISTIVE TOUCHSCREEN Operations Manual...

Страница 2: ...g Systems are registered trademarks of GCX Corporation All other trademarks are the property of their respective owners This document is subject to change without notice Planar provides this informati...

Страница 3: ...The Display Controls 13 Adjusting the Medical Monitor s Display 14 On Screen Display Lockout 14 OSD Main Menu 15 Quick Adjustment Functions 17 Power Switch 17 Technical Information 18 Planar D6015TM...

Страница 4: ...gure 4 Screen Angle Settings 10 Figure 5 Connecting Power to the Monitor 10 Figure 6 Connecting the Monitor to Your System 11 Figure 7 Connecting the Stereo Speakers 11 Figure 8 Monitor Display Contro...

Страница 5: ...reatly reducing the radiation related health concerns associated with CRT monitors Functional Description The Planar D6015TM Series Medical Monitor consists of a low profile molded plastic monitor hea...

Страница 6: ...des cleaning with a damp wrung out mild soapy cloth Protection from various chemicals used for cleaning and protection from liquids consistent with these cleaning procedures is provided in accordance...

Страница 7: ...rd or cable is frayed or damaged immediately replace it with a another of the same type and rating as supplied by Planar See Ordering Information for part numbers Safety and regulatory listings and ce...

Страница 8: ...lass B computing devices in a typically configured system It is the system integrator or configurer s responsibility to test and ensure that the entire system complies with applicable EMC laws Planar...

Страница 9: ...an only be accomplished in the configured medical device or system and is the responsibility of the device or system manufacturer Planar has the necessary documentation such as IEC 60601 1 notified bo...

Страница 10: ...contact customer service for assistance Keep all packing material in case you need to ship or store the monitor in the future or in case of return After you unpack the monitor make sure the following...

Страница 11: ...nd lower button to increase or decrease the setting of the selected function See Quick Adjustment Functions on page 17 for additional features of these buttons 4 Power Switch On Screen Display OSD Pus...

Страница 12: ...for Optional Touchscreen Connect the cable provided with the touchscreen package to this port and to your system s 9 pin serial port 4 Audio Line in Port Connect the system s audio line out to this p...

Страница 13: ...nload Drivers page select the appropriate platform and download the driver file and the instruction file Following driver software installation you will need to calibrate your touchscreen to the compu...

Страница 14: ...the female end of the mains AC power cord into the AC power adapter then plug the power connector of the adapter into the power port on the monitor The port 12 Vdc is located at the rear of the monito...

Страница 15: ...until it receives a video signal from the system Connecting Optional Stereo Speakers Connect the supplied audio cable to the line out port of your computer s audio card Next connect the other end of t...

Страница 16: ...signal as shown in the table below Mode DC Input Power monitor only AC Input Power incl AC adapter LED Status On with audio On without audio 30 0 W max 28 0 W max 40 W max 37 W max Steady Green Steady...

Страница 17: ...es Medical Monitor are five buttons for operating the monitor and accessing the functions on the On Screen Display OSD Button 1 Function select up 2 Function select down 3 Adjustment increase 4 Adjust...

Страница 18: ...uick and easy When the OSD is on use the Function buttons and to scroll through the menu items Use the Adjustment buttons and to advance to the next sub menu and make changes to the selected menu item...

Страница 19: ...Change display size position clock and phase etc AUTO ADJUST Automatically adjust the picture quality and alignment It is recommended you use this function in Windows or similar environments this func...

Страница 20: ...o 6500 Kelvin USER Enable the User Color field and adjust individual RGB levels TO MAIN MENU Return to Main Menu Miscellaneous Menu AUDIO VOLUME Adjust the audio volume of the monitor s speakers on mo...

Страница 21: ...ness icon Use the Adjustment buttons to increase or decrease the Brightness level Press the upper or lower Adjustment button or to enable the small Volume icon Use the Adjustment buttons to increase o...

Страница 22: ...VGA compatible analog RGB 15 pin D Sub Separate Sync Composite Sync Scanning Frequency 24 61 kHz horizontal 50 90 Hz vertical Factory Preset Modes 25 Power Management Meets VESA DPMS EPA Power Consump...

Страница 23: ...NEC PC98 400 105 640x400 31 500 70 150 25 197 NEC PC98 400 106 640x350 31 469 70 087 25 175 VGA 350 107 640x350 37 861 85 080 31 500 VESA 350 108 640x480 31 469 59 940 25 175 VGA 480 109 640x480 35 00...

Страница 24: ...alent Description Pin Pin Description Red Video 1 9 NC Green Video 2 10 Logic Ground Blue Video 3 11 NC NC 4 12 SDA DDC1 2B Logic Ground 5 13 H sync Red Video Ground 6 14 V sync Green Video Ground 7 1...

Страница 25: ...Operations Manual OM700 02 21 Mechanical Outline Drawings All dimensions shown in the following drawings are specified in millimeters Figure 11 GCX VESA Mounting Option...

Страница 26: ...22 Operations Manual OM700 02 Figure 12 Desk Stand Option Figure 13 Display Front...

Страница 27: ...lay for more information PROBLEM Display is Unclear and Unstable It is best to adjust the display using an image of vertical lines In Windows load a wallpaper bitmap that has vertical lines in it or y...

Страница 28: ...sistance 3 Turn the monitor off and then turn it back on again Press the upper Function button once and then press the upper Adjustment button several times If there is still no display press the lowe...

Страница 29: ...st a Return Material Authorization Number If the configuration has been modified in any manner the product must be returned to its original configuration before any warranty service will be performed...

Страница 30: ...vice If your Medical Monitor needs service call Planar Customer Service at 1 503 690 6960 between 7 00 a m and 4 00 p m PST Monday through Friday or fax to 1 503 748 7085 You will need the unit s seri...

Страница 31: ...ical Monitor Resistive Touchscreen D6015TM TR 15 Inch XGA Medical Monitor Resistive w deskstand 996 0431 00 996 0432 00 996 0435 00 996 0436 00 996 0433 00 996 0434 00 Planar power adapter model PPA45...

Страница 32: ......

Страница 33: ...OR 97006 1992 Tel 1 503 690 1100 Fax 1 503 690 1493 sales planar com app_eng planar com Planar Systems Inc Olarinluoma 9 P O Box 46 FIN 02201 Espoo Finland Tel 358 9 420 01 Fax 358 9 420 0200 intlsal...

Отзывы: