background image

 

 

15

 

Troubleshooting 

 

This LCD Monitor has pre-adjusted using factory standard VGA timings. Due to the output timing differences among 
various VGA cards in the market, users may initially experience an unstable or unclear display whenever a new display 
mode or new VGA card is selected. 

Attention 

This LCD Monitor Supports Multiple VGA Modes.   

Refer to the Standard Timing Table for a listing of modes supported by this LCD Monitor. 

 

PROBLEM    Picture is unclear and unstable

 

The picture is unclear and unstable, please perform the following steps: 

1.

 

Enter PC to “Shut Down Windows” status while you’re in MS-Windows environment. 

2.

 

Check the screen to see if there’s any black vertical stripes appear. If there are, take advantage of the “Clock” 
function in OSD menu and adjust (by increment or decrement numbers) until those bars disappear. 

3.

 

Move to “Phase” function in OSD menu again and adjust the monitor screen to its most clear display. 

4.

 

Click “No” on “Shut Down Windows” and back to the normal PC operating environment. 

 

PROBLEM    There is no picture on LCD Monitor 

If there’s no picture on the LCD Monitor, please perform the following steps: 

1.

 

Make sure the power indicator on the LCD Monitor is ON, all connections are secured, and the system is 
running on the correct timing. Refer to Chapter 3 for information on timing. 

2.

 

Turn off the LCD Monitor and then turn it back on again. If there is still no picture, press the Adjustment 
Control button several times.     

3.

 

If step 2 doesn’t work, connect your PC system to another external CRT. If your PC system Functions properly 
with a CRT Monitor but it does not function with the LCD Monitor, the output timing of the VGA card may be 
out of the LCD’s synchronous range. Please change to an alternative mode listed in the Standard Timing 
Table or replace the VGA card, and then repeat steps 1 and 2.     

 

PROBLEM    There is no picture on LCD Monitor   

If you have chosen an output timing that is outside of the LCD Monitor’s synchronous range (Horizontal: 30 ~ 
80 kHz and Vertical: 56 ~ 75 Hz), the OSD will display a “Out of Range” message. Choose a mode that is 
supported by your LCD Monitor. 

Also, if the signal cable is not connected to LCD monitor at all or properly, the monitor screen will display a 
message “No Input Signal”. 

Содержание PL2010MW

Страница 1: ...PL2010MW...

Страница 2: ...y 5 Connecting the AC Power 6 Connecting the Audio Cable 6 Connect the other end of the audio cable to the LCD Monitor s LINE IN jack 6 Setting Up the LCD Monitor 6 Power Management System 6 Display C...

Страница 3: ...tion Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception whichcanbe determinedbyturningtheequipmentoffandon theuserisencouragedtotrytocorrecttheinterferencebyoneormoreof thefollowi...

Страница 4: ...om with a room temperature of 20 60 C or 4 140 F Storing the LCD Monitor outside this range could result in permanent damage 6 If any of the following occurs immediately unplug your monitor and call a...

Страница 5: ...ent airflow Though the LCD Monitor uses very little power some ventilation is needed to ensure that the Monitor does not become too hot After you unpack the LCD Monitor make sure that the following it...

Страница 6: ...the hinge to release 2 1 Figure 1 3 Interface for Arm Applications Before installing to mounting device please refer to Fig 1 3 The rear of this LCD display has four integrated 4 mm 0 7 pitch threade...

Страница 7: ...sure the AC power cord is connected to the LCD Monitor 2 Turn on the LCD Monitor s power switch located on the bezel of the monitor Power Management System This LCD Monitor complies with the VESA DPM...

Страница 8: ...de be dark when monitor in off mode 2 Power ON OFF switch Push to power on or power off Toggle switch 3 Menu Enter Shows main OSD menu Enter key in OSD menu Audio mute and unmute must activate Volume...

Страница 9: ...res and photographs appear in vibrant colors with sharp detail GAME Enhances color TEXT Optimal balance of brightness and contrast prevent eyestrain The most comfortable way to read onscreen text Pres...

Страница 10: ...d green blue intensity Volume Adjusts the volume of audio D SUB Selects input signal to analog D Sub Input Select DVI Selects input signal to digital DVI Resolution Select 720 640x400 70hz 1360 1280 1...

Страница 11: ...ons The monitor will show an OSD Lock out message for 5 seconds and the message will disappear automatically Repeat this step to unlock Option 2 OSD Power button lock all 5 buttons including the POWER...

Страница 12: ...ut LED Color DPM On 35 W maximum 240 VAC Green DPM Off 1 W maximum 240 VAC Yellow DC switch Off 1 W maximum 240 VAC Dark Disconnected 1 W maximum 240 VAC Meeting VESA DPM requirements measured from AC...

Страница 13: ...C 4 F to140 Storage Condition Relative Humidity 5 to 85 Power Supply AC Input Input Voltage Single phase 100 240VAC 50 60 Hz Input Current 1 0 A maximum Size and Weight Dimensions 476 W x 347 6 H x 19...

Страница 14: ...15 VESA 1024 768 60Hz 4 3 PC 65 00 16 VESA 1024 768 70Hz 4 3 PC 75 00 17 VESA 1024 768 75Hz 4 3 PC 78 75 18 VESA 1152 864 75Hz 4 3 PC 108 00 19 SUN 1152 900 66Hz 3 84 3 PC 94 50 20 VESA 1280 960 60Hz...

Страница 15: ...z d 4 3 PC 121 75 48 1400x1050 75Hz 4 3 PC 156 00 49 1680X1050 60Hz 16 10 PC 146 25 50 1280 X768 60Hz Red Blanking 16 9 6 PC 68 25 51 1280 X768 60Hz 16 9 6 PC 79 5 52 1280 X768 75Hz 16 9 6 PC 102 25 5...

Страница 16: ...is no picture on LCD Monitor If there s no picture on the LCD Monitor please perform the following steps 1 Make sure the power indicator on the LCD Monitor is ON all connections are secured and the s...

Страница 17: ...nitor touch screen or other Planar products visit our online store at www PlanarOnline com or find other stores who carry Planar products at http www planar com howtobuy Technical Support Visit Planar...

Страница 18: ......

Отзывы: