EL512.256-H Series Operations Manual (020-0354-00A)
10
Operational Specifications
Environmental
Table 7. Environmental Characteristics.
Temperature
Operating
H2
H3
0…+55°C
–25…+65°C
Non-operating –40…+75°C
Operating Survival
H2
H3
–20…+65°C (no permanent damage)
–40…+65°C (no permanent damage)
Test duration 24 h at temperature extremes (without condensation)
Humidity
Relative Humidity
+40°C, 93% RH, Operating (IEC 68-2-3)
Damp Heat
+25…+55°C, 95% RH, Non operating (IEC 68-2-30)
Altitude
Operating
15,000 m (50,000 ft.) above sea level
Vibration
20…500
Hz
ASD level 0.05 G
2
/Hz
Random vibration wide band
IEC 68–2–36, Test Fdb
Shock
Magnitude
Duration
Number of shocks
100 G
4 ms (half sine wave)
18 (3 on each of the 6 surfaces)
IEC 68-2-27, test Ea
Reliability
MTBF > 30,000 h @ 25°C
Safety
The display will not inhibit the end product from obtaining the following
specification: UL544
For ordering information of el512-256-h3-frb and other EL Displays, please visit http://www.eldisplays.com/el512-256-h3-frb/ or call +1-888-394-4998.