PKP DU06 Series Скачать руководство пользователя страница 2

Table of Contents

Safety Information................................................................................................................................2
Functional description..........................................................................................................................3
Installation location..............................................................................................................................3
Electrical connection............................................................................................................................4
Menu navigation...................................................................................................................................5
Output parameter <Output Parms> Menu 1.........................................................................................5
Instrument parameter <Instrument Parms> Menu 2.............................................................................7
Mathematical parameters <Math.Parms> Menu 3...............................................................................9
Instrument test function <Instr. Test> Menu 4...................................................................................10
Error messages....................................................................................................................................11
Functional check.................................................................................................................................11

Safety Information

General Instructions

To   ensure   safe   operation,   the   device   should   only   be   operated   according   to   the
specifications in the instruction manual. The requisite Health & Safety regulations for a
given   application   must   also   be   observed.   This   statement   also   applies   to   the   use   of
accessories.
Every person who is commissioned with the initiation or operation of this device must have
read and understood the operating instructions and in particular the safety instructions! 

The liability of the manufacturer expires in the event of damage due to improper use, non-
observance   of   this   operating   manual,   use   of   insufficiently   qualified   personnel   and
unauthorized modification of the device. 

Proper Usage

The ultrasonic flow meter Du06 are designed to measure the flow of liquids which do not
attack the device materials. All other usage is regarded as being improper and outside the
scope of the device. 

In   particular,   applications   in   which   shock   loads   occur   (for   example,   pulsed   operation)
should be discussed and checked in advance with our technical staff.

The series DU06 flow meter devices should not be deployed as the sole agents to prevent
dangerous conditions occurring in plant or machinery. Machinery and plant need to be
designed in such a manner that faulty conditions and malfunctions do not arise that could
pose a safety risk for operators.

Dangerous substances

For dangerous media such as e.g. Oxygen, Acetylene, flammable or toxic substances as
well as refrigeration systems, compressors, etc. must comply with the relevant regulations
beyond the general rules.

DU06 Instruction manual 09/2019

page  2

Содержание DU06 Series

Страница 1: ...Instruction Manual DU06 Ultrasonic flowmeter with display PKP Prozessmesstechnik GmbH Borsigstra e 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email info pkp de...

Страница 2: ...vent of damage due to improper use non observance of this operating manual use of insufficiently qualified personnel and unauthorized modification of the device Proper Usage The ultrasonic flow meter...

Страница 3: ...on versions are available version made of brass or stainless steel flow max 80 l min 1 version made of stainless steel flow max 180 l min 2 version made of stainless steel flow max 1000 l min All vers...

Страница 4: ...urrent voltage frequency output 4 pole plug included in delivery Pin 1 4 20mA 0 10V Freq Out Pin 2 GND Pin 3 GND Pin 4 24VDC 15 Relay outputs 6 pol plug included in delivery Pin 1 Relay 2 normally ope...

Страница 5: ...parameter Output Parms Menu 1 Relay 1 setting switch point of relay 1 Relay 2 setting switch point of relay 2 If the actual measured flow exceeds falls below one of the adjusted switch points the re...

Страница 6: ...erated Freq Out 0 Hz is generated Assignment of analog output signal If the analogue output is used the following assignment must be observed 20 mA corresponds to the Max Flow Limit 4 mA corresponds t...

Страница 7: ...c Litre per second l min Litre per minute l h Litre per hour m min Cubic meter per minute m h Cubic meter per hour gal sec Gallons per second gal min Gallons per minute gal h Gallons per hour Percent...

Страница 8: ...e flow passing the DU06 during power failure was not counted Parameter protection Pin Pin Code is for protecting parameter of the device Changing them without authority will be avoided If the Pin is a...

Страница 9: ...fset This function is used for adaption of the characteristic diagram up to formula Qkorr Qist DynOffset Qist QmaxPhys With Qist measured flow Qkorr corrected flow QmaxPhys max flow in pipe at v 5m se...

Страница 10: ...s and protected due to manufacturers code 4 20 mA K value of current output 4 20 mA K Value This function is for special applications and protected due to manufacturers code 0 10 V K value of voltage...

Страница 11: ...dium The DU06 indicates no negative flow If there is 0 flow indication while there is flow flow direction has to be changed in the program Functional check It is the responsibility of the operator to...

Страница 12: ...time difference is proportional to the flow rate In contrast to other types of ultrasonic flowmeters the sensors are oriented parallel to the flow stream This results in an extremely compact meter wh...

Страница 13: ...Dimensions Order Code Order number DU06 Ultrasonic flowmeter and counter with local indication E V R025 0 0 Material version M brass housing sensors st steel with R male connection only E st steel ho...

Отзывы: