The series DS04 flow meter devices should not be deployed as the sole agents to prevent
dangerous conditions occurring in plant or machinery. Machinery and plant need to be
designed in such a manner that faulty conditions and malfunctions do not arise that could
pose a safety risk for operators.

Dangerous substances

For dangerous media such as e.g. Oxygen, Acetylene, flammable or toxic substances as
well as refrigeration systems, compressors, etc. must comply with the relevant regulations
beyond the general rules. 

Qualified Personnel

The DS04 devices may only be installed by trained, qualified personnel who are able to
mount   the   devices   correctly.   Qualified   personnel   are   persons,   who   are   familiar   with
assembling, installation, placing in service and operating these devices and who are suit-
ably trained and qualified.

Inward Monitoring

Please check directly after delivery the device for any transport damages and deficiencies.
Additional with reference to the accompanying delivery note the number of parts must be
checked.
Claims for replacement or goods which relate to transport damage can only be considered
valid if the delivery company is notified without delay.

Overview

1: Process connection (outlet)

2: Device body

3: Switch contact and female socket or switch contact

with cable

4: Switch point adjustment scale

5:   Display   housing   with   display   scale   and   pointer

mechanism

6: Process connection (inlet) 

DS04 Instruction manual  03/2020

page  3

Содержание DS04.1

Страница 1: ...anual DS04 All Metal Variable Area Flowmeter and Switch High Pressure Version PKP Prozessmesstechnik GmbH Borsigstra e 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email...

Страница 2: ...improper use non observance of this operating manual use of insufficiently qualified personnel and unau thorized modification of the device Proper Usage The variable area flowmeters of the DS04 series...

Страница 3: ...mount the devices correctly Qualified personnel are persons who are familiar with assembling installation placing in service and operating these devices and who are suit ably trained and qualified Inw...

Страница 4: ...damage to the flow monitor or the system a process connection suitable for the device must be provided by the customer check connection size and screw in depth use suitable sealants liquid sealants da...

Страница 5: ...e case of liquid media take appropriate steps to ensure that the device is ven ted to ensure measuring accuracy the device must always be completely filled with medium vent the pipeline If there are a...

Страница 6: ...ower The Reed contact integrated in the switching unit is very sensible to electrical over load Danger of overload is given by the following applications inductive load capacitive load lamp load Induc...

Страница 7: ...directly connected to the input terminals of a PLC without problems RC Circuits as protective measures Boucherot cell Snubber In practice the following values of resistor capacitor cells give good re...

Страница 8: ...re that the device is grounded via the pipeline This prevents dangerous potential differences from occurring Switching capacity of contacts Switching capacity Type Size Contact function Angle plug IP6...

Страница 9: ...or acc to EN 175301 803 Normally Open NOC Change Over COC Switch position under no flow condition Switch position under no flow condition The ground pin is not used The ground pin is not used DS04 Ins...

Страница 10: ...der no flow condition Switch position under no flow condition Switching contact with cable The individual cores of the cable are numbered according to the following connection dia gram Normally Open N...

Страница 11: ...2 Slide the switch contact to the flow value to be monitored Make sure that the arrow on the switch contact label is in exact alignment with the desired flow value on the body scale 3 Re tighten the...

Страница 12: ...Switch contact is permanently switched Flow is too high or the switch contact is set too low Reduce the flow Adjust the switch contact to a higher flow rate Use the device at another measuring range...

Страница 13: ...s and circumstances Maintenance work Visual inspection for dirt soiling Visual inspection for free movement of float Visual inspection for leaks from the device Check function of switch contact For de...

Страница 14: ...s following the float position indicates the flow rate on a scale A Reed contact is mounted outside the meter in a sealed housing When the float reaches the position of the Reed contact the switch wil...

Страница 15: ...1 4 1N 1 4 NPT 1A G 3 8 1AN 3 8 NPT 2 G 1 2 2N 1 2 NPT 3 G 3 4 3N 3 4 NPT 4 G 1 4N 1 NPT Material 1 brass nickel plated 2 stainless steel 1 4571 Scale 1 for water 2 for air at 1 bar abs 20 C Measurin...

Страница 16: ...800 900 05 27 32 30 35 47 47 71 71 1 2 3 4 19 17 146 174 800 850 960 1010 06 07 08 34 40 50 40 40 40 57 57 67 76 76 81 3 4 1 1 18 19 20 152 156 200 1350 1400 1050 1100 2750 2800 PKP Prozessmesstechnik...

Страница 17: ...r operating densities deviating from the specified specifications increase the specified measuring error Special scales for different media and operating conditions are available on request The specif...

Отзывы: