Models:
Measuring ranges:
water:
0,1–1,5 l/min ... 4–50 l/min
air:
1–28 Nl/min ... 200–1450 Nl/min
(referenced to 1 bar abs, 20°C)
Materials:
brass (nickel plated) or
stainless steel versions
Technical Data:
Max. pressure:
brass version: 200 bar
stainless steel version: 300 bar
Pressure loss:
0,02–0,2 bar (for liquids)
0,02 – 0,4 bar (for gases)
Max. media-
temperature:
100 °C for liquids (optional 160 °C)
80 °C for gases,
Ex-devices acc. to. ATEX-marking
Operating temp.:
70 °C with analogue transmitter AZ06
Electr. Con.:
angle plug acc. to EN 155301-803,
Form A (DIN 43650),
Ex-contact with 2 m cable,
optional:
cable connection
round plug M12 x 1 acc. to EN 50044
angle plug with LED or glow lamp
Accuracy:
± 5 % of full scale for liquids
± 10 % of full scale for air
Mounting position:
vertical
Materials:
Brass version
(nickel plated):
Wetted parts:
float:
brass nickel plated (for liquids)
POM (for gases)
threaded rings: brass
gaskets:
NBR (optional FKM, EPDM)
all other wetted parts: brass nickel plated
Stainless steel version 1.4571:
Wetted parts:
float:
stainless steel 1.4571 (for liquids)
POM (for gases)
gaskets:
FKM
(optional NBR, EPDM)
all other wetted parts: stainless steel 1.4571
Order Code:
Order Number: DS04.
variable area flow meter-
and switch
3. 1. 1. WA06. 1. 1. 1. 0
Connection female thread:
1 = G 1/4
1N = 1/4“ NPT
1A = G 3/8
1AN = 3/8“ NPT
2 = G 1/2
2N = 1/2“ NPT
3 = G 3/4
3N = 3/4“ NPT
4 = G 1
4N = 1“ NPT
Material:
1 = brass nickel plated
2 = stainless steel 1.4571
Scale:
1 = for water
2 = for air (at 1 bar abs., 20 °C)
Measuring ranges:
Water
Air
DS04.1, DS04.1A and DS04.2:
WA01 = 0,1–1,5 l/min
LA01 = 1–28 Nl/min
WA02 = 0,2 –3 l/min
LA02 = 4–60 Nl/min
WA03 = 0,3–8 l/min
LA03 = 6–160 Nl/min
WA04 = 1–12 l/min
LA04 = 20 –240 Nl/min
DS04.2 and DS04.3:
WA05 = 2 –18 l/min
LA05 = 40 –360 Nl/min
DS04.3 or DS04.4:
WA06 = 3–35 l/min
WA07 = 4–50 l/min
LA07 = 60–700 Nl/min
only DS04.4:
LA08 = 200 –1450 Nl/min
Addition S...= special scale
Flow indicator:
0 =
switch only, without flow indicator
1 =
flow meter and -switch, with flow indicator
Number of contacts:
0 =
without contact (only for devices with indication and/or AZ06)
1 = 1 contact
2 = 2 contacts
Contact function / Analogue output:
(contact or analogue transmitter available)
0
= without
1
= N/O
2
= SPDT
2X = SPDT for SPS application
3ST5 = Ex-N/O, T5 (100 °C), with 2 m cable
3ST6 = Ex-N/O, T6 (80 °C), with 2 m cable
3UT5 = Ex-SPDT, T5 (100 °C), with 2 m cable
3UT6 = Ex-SPDT, T6 (80 °C), with 2 m cable
AZ06.1.I = analogue transmitter 4...20 mA
AZ06.1.V = analogue transmitter 0...10 V
Options:
0 = without
1 = please specify in plain text
HT = high temperature version 160 °C (for liquids only)
M12 = round plug M12 x 1 acc. to EN 50044 (Tmax. 85 °C)
Kx = cable version 1 m, 2 m, 5 m, or 10 m
PKP Prozessmesstechnik GmbH
Borsigstr. 24 • D-65205 Wiesbaden
S
+49 (0) 6122-7055-0 •
T
+49 (0) 6122 7055-50
[email protected] • www.pkp.de
Fl
ow