Flow Measurement and Monitoring

DS04

Variable Area Flowmeter
and Switch for High Pressure
Applications

applicable for low viscosity liquids and gases

small mounting dimensions

brass (nickel plated) or stainless steel version

high switching accuracy

robust design without a measuring glass tube

for process pressure up to 300 bar

      optional Ex- version acc. to ATEX

analogue transmitter 4...20 mA available

Description:

The flowmeter and switch model DS04 works according to a
modified variable area principle.
The float is guided in 

an upward tapered measuring tube

. The

flowing   medium   moves   the   float   in   the   flow   direction.   An
externally mounted pointer indicator is magnetically coupled
to the float and thus, following the float position, indicates the
flow rate on a scale.
A Reed contact is mounted outside the meter in a sealed
housing.   When  the   float   reaches   the   position   of   the   Reed
contact   the   switch   will   close.   With   higher   flows   the   float
moves further upward until it reaches a built-in float stop, still
keeping   the   switch   closed.   This   ensures   a   bistable   switch
function at any time. The Reed contact is adjustable over the
full measuring and switching range of the meter.

Typical application:

The variable area flowmeters and monitors DS02 are used to
measure and monitor continuous flow rates of low-viscosity
liquids or gaseous media.

Areas of applications are:

cooling systems

engineering

medical technology

pharmaceutical and chemical industries

research and development

PKP Prozessmesstechnik GmbH

Borsigstr. 24 • D-65205 Wiesbaden

S

 +49 (0) 6122-7055-0 • 

T

 +49 (0) 6122 7055-50

 [email protected] •   www.pkp.de

20200302

Содержание DS04.1

Страница 1: ...anual DS04 All Metal Variable Area Flowmeter and Switch High Pressure Version PKP Prozessmesstechnik GmbH Borsigstra e 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email...

Страница 2: ...improper use non observance of this operating manual use of insufficiently qualified personnel and unau thorized modification of the device Proper Usage The variable area flowmeters of the DS04 series...

Страница 3: ...mount the devices correctly Qualified personnel are persons who are familiar with assembling installation placing in service and operating these devices and who are suit ably trained and qualified Inw...

Страница 4: ...damage to the flow monitor or the system a process connection suitable for the device must be provided by the customer check connection size and screw in depth use suitable sealants liquid sealants da...

Страница 5: ...e case of liquid media take appropriate steps to ensure that the device is ven ted to ensure measuring accuracy the device must always be completely filled with medium vent the pipeline If there are a...

Страница 6: ...ower The Reed contact integrated in the switching unit is very sensible to electrical over load Danger of overload is given by the following applications inductive load capacitive load lamp load Induc...

Страница 7: ...directly connected to the input terminals of a PLC without problems RC Circuits as protective measures Boucherot cell Snubber In practice the following values of resistor capacitor cells give good re...

Страница 8: ...re that the device is grounded via the pipeline This prevents dangerous potential differences from occurring Switching capacity of contacts Switching capacity Type Size Contact function Angle plug IP6...

Страница 9: ...or acc to EN 175301 803 Normally Open NOC Change Over COC Switch position under no flow condition Switch position under no flow condition The ground pin is not used The ground pin is not used DS04 Ins...

Страница 10: ...der no flow condition Switch position under no flow condition Switching contact with cable The individual cores of the cable are numbered according to the following connection dia gram Normally Open N...

Страница 11: ...2 Slide the switch contact to the flow value to be monitored Make sure that the arrow on the switch contact label is in exact alignment with the desired flow value on the body scale 3 Re tighten the...

Страница 12: ...Switch contact is permanently switched Flow is too high or the switch contact is set too low Reduce the flow Adjust the switch contact to a higher flow rate Use the device at another measuring range...

Страница 13: ...s and circumstances Maintenance work Visual inspection for dirt soiling Visual inspection for free movement of float Visual inspection for leaks from the device Check function of switch contact For de...

Страница 14: ...s following the float position indicates the flow rate on a scale A Reed contact is mounted outside the meter in a sealed housing When the float reaches the position of the Reed contact the switch wil...

Страница 15: ...1 4 1N 1 4 NPT 1A G 3 8 1AN 3 8 NPT 2 G 1 2 2N 1 2 NPT 3 G 3 4 3N 3 4 NPT 4 G 1 4N 1 NPT Material 1 brass nickel plated 2 stainless steel 1 4571 Scale 1 for water 2 for air at 1 bar abs 20 C Measurin...

Страница 16: ...800 900 05 27 32 30 35 47 47 71 71 1 2 3 4 19 17 146 174 800 850 960 1010 06 07 08 34 40 50 40 40 40 57 57 67 76 76 81 3 4 1 1 18 19 20 152 156 200 1350 1400 1050 1100 2750 2800 PKP Prozessmesstechnik...

Страница 17: ...r operating densities deviating from the specified specifications increase the specified measuring error Special scales for different media and operating conditions are available on request The specif...

Отзывы: