NOTICE!
For information about the distance between the hob
and a cooker-hood look at the instruction manual of
the manufacturer.
Preparation and fixing
1.
Remove the adhesive paper and stick
the seal provided with the appliance
all around the hob.
2.
Place the hob into the hole in the
cupboard pressing it firmly so that it
is closed off by the seal.
3.
Fix the four clips on the bottom of the hob into the holes at the corners of the
cupboard.
4.
Note
– Some appliances do not need the clips.
Electrical connection
DANGER!
The appliance must be connected to the mains by a qualified
professional, who is familiar with and adheres to the local requirements
and supplementary regulations of your electricity supplier.
1.
When the socket is not accessible for the user
or a fixed electrical connection
of the appliance is required
, an all-pole disconnecting device must be
incorporated during installation. Disconnecting devices are switches with a
contact opening distance of at least 3 mm. These include LS-switches, fuses and
protectors (EN 30335).
2.
The cable must be able to withstand a temperature of 120
0
C. The appliance
must be grounded properly. Switch off the current before installation.
3.
Read the information on the model plate and the connection diagram.
Technical Data
VOLTAGE
TOTAL
POWER
NOMINAL POWER
PER PHASE
PROTECTION
400V
7,2 KW
31,5 A
32 A
The connection work must be carried out by a qualified professional only.