![Pkm GSP600 Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/pkm/gsp600/gsp600_instruction-manual_1561042047.webp)
47
❖
The voltage and the frequency of the power supply must meet the data on the
rating plate.
❖
If any malfunction occurs, the grounding will reduce the risk of electric shock as
the electrical flow will prefer the way of 'least resistance.
❖
If you are in doubt that the appliance is grounded properly, a qualified
professional should check the status of the electrical installation (not included in
guarantee).
2.4 Water supply
The water pressure must be between 0.04 and 1 MPa. Ask the aftersales service if
the water pressure has different values.
Cold water supply
. Connect the cold water hose to a 3/4 inches thread. When the
hoses are new or were not used for an extended period of time, let the water flow
until it is clear of any contamination. Otherwise the water inlet will be blocked and
the appliance damaged.
1
Pull the complete hose out of its storage compartment
at the back of the appliance.
2
Fix the hose with the 3/4 inches thread on the tap.
3
Open the water supply completely before you operate
the appliance.
NOTICE!
A hose that attaches to a sink spray can burst if it is installed
on the same water line as the dishwasher. If your sink has one, it is
recommended that the hose be disconnected and the hole plugged.
Disconnection of the water supply.
Turn off the water supply completely.
Decrease the water pressure by pressing the pressure reduction button to protect
you and the room from spilled water. Finally remove the hose from the tap.
2.5 Installation of the water drain hose
Insert the drain water hose into a drain pipe with a diameter of at least 4 cm or into
a sink. Do not bend or squeeze the hose. Use the supplied hose support (1). The
free end of the water drain hose must not be higher than 60 cm and must not be
immersed into water to avoid reflux. When installed to a water outlet the hose must
be connected properly to avoid any leaks.