31
NOTICE!
For information about the distance between the hob and a cooker-hood look at the
instruction manual of the manufacturer.
Preparation and fixing
1.
Remove the adhesive paper and
stick the seal provided with the
appliance all around the hob.
2.
The built-in opening must be
clean, dry and free from grease.
3.
Insert the appliance in the built-in
opening and press it firmly so
that the seal fits closely.
Electrical connection
DANGER!
All electric work must be performed by an authorized professional.
The connection of the appliance must be performed in compliance with this
instruction manual. An incorrectly performed installation may cause serious injuries
to individuals or animals and also cause serious damage to your property.
Do not carry out any alterations or wilful changes in the electricity supply.
1.
Switch off the current before installation.
2.
A proper grounding is necessary and a switch for disconnecting all phases must
be placed accessibly with a minimum distance of 3 mm between the contacts.
Technical Data
VOLTAGE
TOTAL
POWER
NOMINAL POWER
PER PHASE
PROTECTION
400V
6.0 KW
26.1 A
32 A
The connection work must be carried out by a qualified professional only.
The connection diagram is on the cover of the connection box. Remember that
the connection wire should match the connection type and the power rating of
the oven.
The connection cable must be secured in a strain-relief clamp.