~
100
~
➢
Move a screwdriver (
1
) slightly downwards (
2
) to open the box.
WARNING!
Any damages which are caused by an appliance that is
not connected to the mains properly are
not
subject to the guarantee!
2.4.1 Connection diagram
Voltage heating elements 230V.
Any kind of connection: the
safety wire must be connected
to the PE terminal.
Recommended
type of
connection
lead.
1
➢
For 230 V earthed one-
phase connection.
➢
Bridges connect 1 - 2 - 3
terminals and 4 - 5
terminals.
➢
Protective ground to
H05VV-F3G4
2
➢
For 400 / 230 V earthed
two-phase connection.
➢
Bridges connect 2 - 3
terminals and 4 - 5
terminals.
➢
Protective ground to
H05VV-F4G2,5
3
➢
For 400 / 230 V earthed
three-phase connection.
➢
Bridges connect 4 - 5
terminals,
phases
in
succession 1, 2 and 3,
Neutral to 4 - 5.
➢
Protective ground to
H05VV-F5G1,5
L1=R, L2=S, L3=T
N= Earth
PE= earth wire terminal
Содержание BIC8 2KB-DPY
Страница 22: ... 22 ABB 1 ABB 2 ...