 8  TECHNICAL DATA

8.1 General data

SIL level (SIL CL): 

up to SIL 3 according to 

 

EN 62061+A1:2013 / IEC 61508:2010

Performance level (PL): 

up to PL e according to EN ISO 13849-1:2008

Safety category: 

up to Category 4 according to EN ISO 13849-1:2008

MTTF

d

: 289 

PFH

d

: 8.38E-09

Mission time: 

20 years

Response time: 

< 30 ms

Ambient temperature: 

0°C ... +55°C

Storage temperature: 

-20°C ... +70°C

Pollution degree: 

outside 3, inside 2

Over-voltage category: 

II

Weight: 

250 gr

 

8.2 Housing

Material: 

Polyamide PA 6.6 class V0 (UL94)

Protection degree: 

IP40 (housing) IP20 (terminals)

Dimensions (L x H x S): 

111.5 x 99 x 67,5 mm

Cross section of the conductors: 

0.2 ... 2.5 mm

2

 

24 ... 12 AWG

Terminals driving torque: 

0.5 ... 0.6 Nm

Mounting:  

Din-rail 35x7.5 (EN 50022)

 

8.3 Supply

Rated operating voltage A1-A2 (U

n

): 

24 Vdc

Max residual ripple in DC: 

10%

Supply voltage tolerance:  

- 15% ... +15% di Un

Rated power consumption (without load): 

< 3 W

Internal general protection: 

PTC, Ih=1.5 A

Operating time of PTC:  

intervention > 100 ms, reset > 3 s

Internal protection against outputs  
(Tx, Ox) short circuits: 

electronic

Max outputs (Tx, Ox) currents sum: 

0.5 A

Self test time at start up: 

< 2 s

 

8.4 Input circuits (Ix)

 

Number of inputs:  

8

Voltage and current on input circuits: 

24 V, 5 mA

Inputs signal: 

0-8 V (Off), 12-24 V (On)

Galvanic separation: 

No

Minimum input signal period: 

10 ms

Input signal filtering:  

Yes, max spike length 0.4 ms

Max input resistance: 

100 Ohm

Max input capacity: 

470 nF toward ground

 

470 nF between the conductors

 

8.5 Decoupled input circuits (Jx)

Number of inputs:  

4

Input circuits voltage and current:  

24 V, 5 mA

Input signals: 

0-8 V (Off), 12-24 V (On)

Galvanic separation: 

Yes

Insulation voltage (Ui): 

500 V

Minimum duration of input signal: 

10 ms

Input signal filtering: 

Yes, maximum interference period 0.4 ms

Maximum input resistance: 

100 Ohm

Maximum input capacitance: 

470 nF to ground

 

470 nF between the two conductors

NB: Voltage and current values indicated refer to the power supply terminals (Ax, see each module individually) of the 
board housing the Jx type terminals

8.6 Analogue input circuits (Cx)

Number of inputs:  

2

Rated supply voltage: 

24 Vdc ± 15 %

Analogue input type: 

4-20 mA current loop

Measurement range: 

0 … 25 mA

Accuracy over entire measurement range: 

1 % ± 1 digit

Resolution: 

0.01 mA

Input resistance: 

100 Ohm

Maximum applicable current: 

30 mA

Managed sensors: 

“source” type with 2/3 wires

Galvanic separation: 

Yes

Insulation voltage (Ui): 

500 V

NB: Voltage and current values indicated refer to the power supply terminals (Ax, see each module individually) of the 
board housing the Cx type terminals

8.7 Frequency input circuits (Fx)

Number of inputs:  

4

Rated supply voltage: 

24 Vdc ± 15 %

Input circuit voltage and current:  

24 Vdc, 7 mA

Supply voltage check of 
proximity sensors on power supply: 

24 Vdc ± 20 %

Maximum detectable frequency: 

4 kHz

Minimum detectable frequency: 

1 Hz

Frequency detection accuracy:  

1 % ± 1 digit

Resolution: 

0.1 Hz

Minimum detection time closed tree:  

1 s

Galvanic separation: 

Yes

Insulation voltage (Ui): 

500 V

NB: Voltage and current values indicated refer to the power supply terminals (Ax, see each module individually) of the 
board housing the Fx type terminals

8.8 Testing signal circuits (Tx)

Test signal number:  

4

Signal type: 

Pulsed 100 Hz 24V/0V, 

 

duty cycle 50% 

Max. total current: 

See 8.3 Supply

Protected against short circuit: 

Yes

Galvanic insulation: 

No

 

8.9 Semiconductor signal output circuits (Ox)

Output number:  

4

Output type: 

PNP

Maximum current per output: 

0.5 A

Max. total current: 

see 8.3 Supply

Impulse voltage (U

imp

): 

0.8 kV

Rated insulation voltage (U

i

):  

32 V

Protected against short circuit: 

Yes

Galvanic separation: 

No

 

8.10 Semiconductor safety output circuits (OSx)

Number of output contacts: 

4

Rated voltage 24V-0V: 

24 Vdc

Output type: 

PNP

Maximum current per output: 

0.5 A

Max. total output current:  

2 A

Minimum current: 

10 mA

Maximum capacitive load to ground per output: 400 nF
Maximum inductive load per output: 

500 mH

Protection fuse: 

2 A type gG

Galvanic separation: 

Yes

Impulse voltage (U

imp

): 

0.8 kV

Rated insulation voltage (U

i

): 

32 V       

Short circuit detection between outputs: 

Yes

Deactivation pulse duration on safety outputs: < 300 µs

8.11 Conformity to regulations

Conforms to the standards: 

 

EN 60947-1, EN 60947-5-1, EN 60204-1, EN 
ISO 13849-1, EN ISO 13855, EN 1037, EN ISO 
12100, EN ISO 13850, EN 60529, EN 61000-6-
2, EN 61000-6-3, EN 62326-1, EN 61326-1, EN 
61326-3-1, EN 60664-1, EN 62061, UL 508, CSA 
C22.2 n° 14-95.

Conforms to the directives: 

2014/35/EU, 2006/42/EC, 2014/30/EU

Clearance and creepage distances in accordance with: EN 60947-1

5/6

 10  TERMINALS LAYOUT

 11  INTERNAL WIRING DIAGRAM

 -

P1

P2

T02 ... T04

T01

J26 ... J28

J25

F1B ... F2B

F1A

OS2

0V

OS3

O02 ... O04

O01

OS4

24V

OS1

A3

A4

A5

C1

C2

A6

A1

A2

I22 ... I41

I21

PWR

O01 O02

I21 I22

O03 O04

OS1 OS2 OS3 OS4

J25 J26

P2

P1

F1A F1B

I23

J27

F2A

I24

J28

F2B

J25

J27 J28

J26

I21

I23 I24

I22

F1A

F2A F2B

F1B

A3

A4 A4

A4

T01

T03 T04

T02

OS1

OS3 OS4

OS2

O01 O02 O03 O04

A1 A2 24V 0V

CS MP307

USB

CH B

C2

I41

I43 I44

I42

CH A

C1

A5

C1 C2

A6

I41

I43 I44

I42

The module is maintenance free.

9 MAINTENANCE

UL APPROVAL NOTES: 

Use 60 or 75 °C copper (CU) conductor and wire size No. 30-12 AWG, stranded or solid. The terminal tightening torque 

is 5 – 7 Lb-In. Supply from Remote Class 2 Source or limited voltage limited energy.

Utiliser des conducteurs en cuivre (Cu) 60 ou 75°C rigides ou flexibles de section 30-12 AWG.  Couple de serrage des 

bornes de 5-7 Lb In. Alimenter avec sources de classes 2 ou avec tension  limitée  et  énergie  limitée.

Содержание CS MP307M0

Страница 1: ...sicurezza sia utilizzato nei limiti d impiego previsti In serie ad ogni uscita di sicurezza a relè installate dei fusibili di valore adeguato al carico solo per versioni con uscite a relè E consigliato alimentare il modulo di sicurezza con una sorgente di alimentazione separata da quella del macchinario e di mantenere separate le connessioni elettriche di potenza da quelle del modulo L alimentazio...

Страница 2: ... mA Resistenza d ingresso 100 Ohm Corrente massima applicabile 30 mA Sensori gestiti tipo source a 2 3 fili Separazione galvanica Sì Tensione di isolamento Ui 500 V NB Le tensioni e correnti indicate fanno riferimento ai morsetti di alimentazione Ax vedi caso per caso ogni modulo della scheda dove sono presenti i morsetti di tipo Cx 8 7 Circuiti di ingresso in frequenza Fx Numero ingressi 4 Tensio...

Страница 3: ...ta Per rilevare il verso di rotazione è necessario che i 2 sensori relativi al medesimo asse siano montati con un angolo di sfasamento pari a 1 4 dell angolo sotteso da un dente ed una cava esempio se la ruota fonica è composta da due denti e due cave l angolo sotteso da un dente e una cava è pari a 180 e l angolo di sfasamento consigliato è pari a 45 Il dente deve comunque garantire la prescrizio...

Страница 4: ...rolled by processors and after power supply they start immediately indicating the relevant input output state When safety module is working without any error in the Normal Operation State the two LEDs P1 P2 of processors are switched off In Normal Operation State the device may intercept some external circuit Malfunctions due to short circuits invalid circuit opening or incorrect status of the inp...

Страница 5: ...Number of inputs 4 Rated supply voltage 24 Vdc 15 Input circuit voltage and current 24 Vdc 7 mA Supply voltage check of proximity sensors on power supply 24 Vdc 20 Maximum detectable frequency 4 kHz Minimum detectable frequency 1 Hz Frequency detection accuracy 1 1 digit Resolution 0 1 Hz Minimum detection time closed tree 1 s Galvanic separation Yes Insulation voltage Ui 500 V NB Voltage and curr...

Страница 6: ...e red red red red Board internal error C2 A6 C1 CS MP307 A5 C2 A6 C1 CS MP307 A5 2 wire sensor schematic 3 wire sensor schematic K8 K7 K7 K8 F Tx Ix 24 Vdc OS1 OS2 K8 K7 K7 K8 F Tx Ix 24 Vdc OS1 OS2 13 INCREASEOFTHENUMBERANDTHELOADINGCAPACITYOFTHECONTACTS If necessary it is possible to increase the number and the loading capacity of the output contacts by using external contactors with forced guid...