background image

 

19

8.3  Remote desktop  
 
The device is integrating Remote Desktop feature. 
This  requires  “cerdisp.exe”  to  be  run  on  the  device  (it  is  already 
pre-installed on it) and , “cerhost.exe” to be run on PC. 
As  a  first  step  the  device  must  be  connected  to  local  network  , 
then double-click the desktop “Cerdisp” icon  

 

 
Click on START icon of the form : 
 

 

 

Содержание TD430

Страница 1: ...Manuale operatore ...

Страница 2: ...2 ...

Страница 3: ...connections 8 6 4 Audio connector 9 6 5 SD MMC connector 10 6 6 USB Device connector 11 6 7 ETD EXP Connector for data acquisition modules 11 7 Setting of dip switches 12 7 1 Serial dip switches 12 7 2 CPU dip switches 14 8 Connecting the Terminal to PC 15 8 1 Connection to PC by ActiveSync 15 8 2 Connection by FTP 17 8 3 Remote desktop 19 9 Auto start of selected applications 20 9 1 Create autoru...

Страница 4: ...nal and HMI Windows CE based Sealing of front panel according to IP54 box sealing according to IP30 2 Ordering codes TD430 AD Touch screen panel 4 3 480x272 Power supply 12 24V AC DC 15 50 60Hz 3 Optional devices ETD884 AD Expansion module for load cells 8 digital I O 2 analogue outputs V mA ...

Страница 5: ... Spessore suggerito 2 mm Suggested thickness 6 87 mm Dima di foratura 132 x 90 mm Frontal panel cut out 33 mm 130 mm SD CARD 17 32mm inserimento Memory Card 32mm insert Memory Card Memory Card optional Cod CARD SD Espansione optional Cod ETD884 AD ...

Страница 6: ...ctive area 4 3 Resolution 480 x 272 Pixel dimension 0 198 x 0 198 mm Colors 16 millions Lamp life 50000 h typical Lamp power 0 66 W Connections Expansion slot 1 data acquisition Slot Communication ports 1 LAN 10 100 Ethernet RJ 45 1 RS485 opto isolated 1 CAN opto isolated I O Port 2 rear USB port 2 0 12 Mbits S 150mA Audio 1 line Out Power supply 12 24V AC DC 15 50 60Hz Power consumption Typical 3...

Страница 7: ... notice the following safety guidelines Separate control lines from power wires Avoid proximity of remote control switches electromagnetic meters powerful engines Avoid proximity of power groups especially those with phase control View of connectors on TD430 AD DIP1 DIP2 ETH1 USB1 M1 ETD EXP SD CARD USB DEVICE JK1 ...

Страница 8: ...or RJ45 Ethernet Connector 10 100 Base T available on rear side of Terminal below terminal block of power supply It allows to connect the device to local network Green led indicates that link is available and device is connected to network Yellow led indicates that data transmission receipt is in progress 6 3 USB connections The device is provided with two USB 2 0 connectors USB1 is located on the...

Страница 9: ...heral devices also when the Terminal is panel mounted USB Peripheral devices include keyboards mouse serial converters barcode readers etc Max current available on USB connector is 150mA If using pendrives the system will rename Harddisk the first inserted pendrive and Harddisk2 the second pendrive 6 4 Audio connector Audio Jack 3 5mm ...

Страница 10: ...er side of the device close to mini usb connector It is push pull type therefore enter memory card till a click is produced and release it see diagram below To extract the Memory press it until a click is produced and pull it TD430 can support SD and MMC memories up to 2GB it does not support SD cards HC The operating system identifies the memory as StorageCard ...

Страница 11: ...ndows based PC 6 7 ETD EXP Connector for data acquisition modules The ETD EXP connector allows quick connection of proprietary expansion slots for data acquisition purpose Please proceed as follows Switch the device off disconnect power supply enter the expansion slot fix the four screws contained in the package connect power supply and switch the device on ...

Страница 12: ...enclosure allowing the user to adapt the device to specific requirements N B Switch the device off and disconnect power supply before proceeding to any hardware setting 7 1 Serial dip switches DIP1 is conceived to set the serial communication It is placed underneath power supply terminal block therefore the terminal block must be removed in order to get access to DIP1 ...

Страница 13: ...ch Input type Dip switch Notes Desabled Default setting CAN Termination Close a termination resistor 120Ohm between CANH and CANL RS485 Termination Close a termination resistor 330Ohm between RS485 and RS485 Polarization RS485 Close polarization resistors on RS485 line ...

Страница 14: ...5 The green LED indicates that data transmission in in progress on RS485 In this case the LED is ON only if dip 3 and 4 of DIP1 are set to ON with consequent polarization of RS485 line 7 2 CPU dip switches DIP2 is located at the bottom of rear side DIP1 DIP2 ETH1 USB1 M1 ETD EXP This dip switch enables desables the protection of flash memory writing Preventing the writing on flash memory it will n...

Страница 15: ...connected to any Windows based PC To connect the device to a PC it is necessary to get a USB type A mini USB type B cable Pixsys code 1620 00 082 and the software ActiveSync for Windows 2000 up to Windows XP or alternatively the Windows Mobile Device Centre for Windows Vista and Windows 7 Both applications are available for free download at www microsoft com After installing the above mentioned so...

Страница 16: ...16 Windows 2000 Windows XP Windows Vista and Windows 7 ...

Страница 17: ...e to explore files and transfer them from PC to device and vice versa 8 2 Connection by FTP TD430 supports FTP protocol and this allows network files transfer between PC and Terminal To access the folders on the device just open Explorer and type ftp anonymous anonymous 192 168 0 100 being 192 168 0 100 the IP address of the device ...

Страница 18: ...taskbar A screenshot containing all details about network will be displayed Anyway we suggest to use an FTP client for data transfer as this is normally simpler and quicker to use An example is FileZilla Client FTP available for free download at http filezilla project org download php ...

Страница 19: ...p feature This requires cerdisp exe to be run on the device it is already pre installed on it and cerhost exe to be run on PC As a first step the device must be connected to local network then double click the desktop Cerdisp icon Click on START icon of the form ...

Страница 20: ...vice 9 Auto start of selected applications The device integrates also the possibility to run automatically some selected applications How it works a link file lnk is created on the Nandflash disk of the device called root from now on and it is named autorun lnk pointing to the application which should be run automatically at startup Autorun lnk files are handled by the software as follows the appl...

Страница 21: ...e if the running application should be closed the device will still display the latest window To remove the autostart it is necessary to connect the device to PC and delete the autorun lnk file Restarting the device it will be possible to visualize the standard desktop To create the autorun lnk file follow the steps below double click My device icon available on desktop and go to the Directory con...

Страница 22: ...ot nandflash or to USB peripheral Harddisk and click Edit and Paste Shortcut Open video keyboard and rename the autorun file Restarting the device the application pointed by the created autorun file will automatically start ...

Страница 23: ...ating system Clicking the keyboard icon on taskbar it is possible to visualize on display two different keyboards keyboard is recommended for TD430 while Large is recommended for Pixsys TD570 and TD700 The operating system includes followings applications Microsoft Word Pad and Windows Media Player 9 Microsoft Word Pad allows to read and create text files directly on the TD430 Windows Media Player...

Страница 24: ...S2005tcp exe application allows to connect the device by Ethernet connection to development environment Visual Studio 2005 All described applications are available for immediate access on desktop of the device ...

Страница 25: ...25 11 Notes Updates ...

Страница 26: ...26 ...

Страница 27: ...27 ...

Страница 28: ...28 ...

Страница 29: ...29 PIXSYS Via Tagliamento 18 30030 Mellaredo di Pianiga VE www pixsys net e mail sales pixsys net support pixsys net 2300 10 134 Rev A 011210 2300 10 134 2300 10 134 ...

Отзывы: