Timer TCT101 can be set in 5 different modes: Timer-ON,
Timer-OFF, Pause-Work, Oscillator, PWM (time-proportioned
output), all options with independent setting of ON-OFF time.
3 digital inputs a re available (NPN/PNP/Potential free
contact) for external commands like Start, Stop, Reset; one
input is also analogic in order to allow the modification of
working times by external potentiometer. 5 different time
bases (hundredths, tenths, seconds, minutes, hours).
1
Safety standards
Carefully read the instructions and safety measures in this
manual before using the device. Disconnect power before
performing any interventions on the electrical connections
or hardware settings. Only qualified personnel may use/
perform maintenance in full respect of the technical data and
declared environmental conditions.
Do not dispose of electrical appliances together with
household waste. In compliance with the European Directive
2002/96/EC, waste electrical equipment must be collected
separately for eco-compatible reuse or recycling.
2
Model Identification
TCT101-1ABC 24..230VAC / VDC +/-15% 50 / 60Hz / 2W
3 digital 2 relays 5 A