18 - ATR902 - User manual
9.5 Waiting step end
This function has been conceived to control kilns working cycles, whenever the
kiln cannot follow gradients programmed by the user. If at step end the diff erence
between process and setpoint values is greater than the value on
parameter 21
m.G.s.e.
, controller starts with the next step only after waiting for the
time programmed on parameter 20
w.t.s.e.
, or when this gap becomes lower than
parameter 21
m.G.s.e.
Temper
atur
e
Time
SETPOINT
Step 1
Step 2
Waiting time step end (Par. 20)
Step and max. gap (Par. 21)
Step 3
PROCESS
To exit manually from this function press
. To disable this function fix at 0 end
step waiting time
w.t.s.e.
. During end step
waiting red display shows
wait
instead of
the cycle number.
9.6 Loading default values
This procedure allows to restore all default settings.
Press
stop
and follow the points below:
Press
Display
Do
1
CYCLE
Press for 5”. Green display shows
0000
with 1st digit fl ashing, red
display visualizes
pass
.
2
STEP
Flashing digit on green
display changes.
Enter the password
9999
.
3
STEP
Device loads default settings.
Entering password
9999
all default parameters will be loaded. If it is necessary to
cancel and reset also the cycles, enter password
9989
.