![Pixsys ATR 621 series Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/pixsys/atr-621-series/atr-621-series_user-manual_1560819046.webp)
46
ATR 621 - User manual
Deviation alarms
5JNFt5FNQP
)ZTUFSFTJTt*TUFSFTJ
OFF
ON
OUT
7BMPSFEJDPOGSPOUP
$PNQBSJTPOWBMVF
(P-47, 54, 61)
PROCESS
PROCESSO
4&510*/5
Alarm can be of:
• Upper deviation
• Lower deviation
In the fi gure it is upper deviation.
Independent alarm reff erring to the setpoint
5JNFt5FNQP
)ZTUFSFTJTt*TUFSFTJ
OFF
ON
OUT
7BMPSFEJDPOGSPOUP
$PNQBSJTPOWBMVF
4&510*/5
(P-47, 54, 61)
Alarm can be:
• Active
over
• Active
under
In the fi gure it is active on.
Each intervention can be related to a cycle lock and/or to an acoustic signalling.
Auxiliary output related to the step
5JNFt5FNQP
4UFQ
4UFQ
4UFQ
4UFQ
4UFQ
4UFQ
Cycle end
'JOFDJDMP
0QFSBUPSTUPQ
4UPQPQFSBUPSF
4FUQPJOU
OFF
ON
OUT
ON/OFF status of the auxiliary
output is selectable for each step
of each cycle. The status can be
selected also at cycle end.
Содержание ATR 621 series
Страница 1: ...ATR 621 Controller Regolatore User manual Manuale d uso...
Страница 2: ......
Страница 9: ...ATR 621 User manual 9 3 Size and installation...
Страница 53: ...ATR 621 Manuale uso 53 3 Dimensioni e installazione...
Страница 98: ...98 ATR 621 Manuale uso...
Страница 99: ......