TROUBLESHOOTING GUIDE
PROBLEM
REASON
SOLUTION
There are no lights on the
chlorine generator and the
pump is not running
1.
There is no mains power
2.
The time clock is in a
designated off period,
or switch moved to OFF
position.
1.
Unplug the chlorine
generator from the power
and test power outlet with
another known working
appliance
2.
Switch to BYPASS to
circumvent TIMER or OFF
functions.
Status Light (3) is on and the
pump is running, but no other
lights are on
The chlorine generator
production is turned off
Adjust control knob
clockwise to increase
production.
The chlorine generator is not
generating enough chlorine
1.
Chlorine production is
reduced on the chlorine
generator.
2.
Chlorine generator is not
operating long enough
3.
Calcified electrode
4.
Water chemistry is
incorrect
1.
Adjust control knob
clockwise to increase
production.
2.
Increase the operation
running time
3.
Clean the electrode
(see maintenance)
4.
Correct water chemistry
Status Light (3) is flashing and
the generator is beeping
1.
The pump is not
running, filtration
blocked, or air locked
2.
Electrode lead not
properly plugged in
1.
A large air bubble in the
electrode housing will
cause this alarm. Clean out
the skimmer box. Check
& clear any blockage. Re-
prime the pump.
2.
Check the electrode lead
plug is properly plugged
onto the electrode