delphin PRO_X QUICK GUIDE
translated from italian
1 - ON-SITE CALIBRATION BY DISPENSING INTO A CALIBRATED CONTAINER
When the DISPLAY displays:
Blinking
Press the ENTER key; it is possible to start the calibration by dispensing the
fluid into a calibrated container.
During dispensing the DISPLAY displays:
Batch total dispensed
Blinking
The dispensing operation may be freely interrupted and resumed.
The Calibration dispensing is finished when the fluid level reaches the grad-
uated area in the calibrated container.
Blinking
Indicated value
To obtain a correct METER calibration, it is necessary:
- To use an accurate sample container having a capacity not less than 5 li-
ters.
- Completely purge all air from the unit before performing the calibration.
- Make the calibration delivery at constant flow rate to be set with the po-
tentiometer
- During the final dispensing phase, do not reduce the flow-rate to reach the
graduated area in the calibrated container.
Press ENTER to confirm the end of the calibration dispensing.
DISPLAY
Sample
container
INDICATED
VALUE
Blinking
REAL
VALUE