delphin PRO - IBC - PRO_X
EN
ACTION
DISPLAY
1
NONE
METER in Standby.
2
MODE
MODE
MODE
LONG MODE KEY KEYING
Meter enters calibration mode, shows “MODE” and displays the
calibration factor being used instead of the partial. The words
“Fact” and “User” indicate which of the two factors (factory or
user) is currently being used.
3
LONG RESET KEY KEYING
The Meter shows “MODE” and the zero partial total.
Meter is ready to perform in-field calibration by dispensing – see
previous paragraph.
4
LONG RESET KEY KEYING
We now go on to Direct change of the calibration factor: the
word “Direct” appears together with the Currently Used calibra-
tion factor. In the bottom left part of the display, an arrow ap-
pears (upwards or downwards) defining the direction (increase
or decrease) of change of the displayed value when subsequent
operations 5 or 6 are performed.
5
SHORT RESET KEY KEYING
Changes the direction of the arrow. The operation can be re-
peated to alternate the direction of the arrow.
6
MODE
MODE
MODE
MODE
SHORT/LONG MODE KEY KEYING
The indicated value changes in the direction indicated by the
arrow
- one unit for every short MODE key keying
- continually if the MODE key is kept pressed. The speed in-
crease rises by keeping the key pressed. If the desired value is
exceeded, repeat the operations from point (5).
7
LONG RESET KEY KEYING
The Meter is informed that the calibration procedure is finished.
Before performing this operation, make sure the INDICATED
value is that required.
8
NO OPERATION
At the end of the calculation, the new USER K FACTOR is shown
for a few seconds, after which the restart cycle is repeated to
finally achieve standby condition.
IMPORTANT: From now on, the indicated factor will become
the calibration factor used by the Meter and will continue to
remain such even after a battery change
9
NO OPERATION
The Meter stores the new work calibration factor and is ready
to begin dispensing, using the USER K FACTOR that has just
been changed.