M0502
18
/28
Installaltion, use and maintenance
13.7 DISPENSING WITH FLOW RATE MODE DISPLAY
It is possible to dispense fluids, displaying at the same time::
1
the dispensed partial.
2
the Flow Rate in [Partial Unit / minute] as shown on the following
display page:
Procedure for entering this mode:
1
wait for the Remote Display to go to Standby, meaning the display screen shows Total only
2
quickly press the MODE key.
3
Start dispensing.
The flow rate is updated every 0.7 seconds. Consequently, the display could be relatively unstable
at lower flow rates. The higher the flow rate, the more stable the displayed value.
ATTENTION
The flow rate is measured with reference to the unit of measurement
of the Partial. For this reason, in case of the unit of measurement of
the Partial and Total being different, as in the example shown below,
it should be remembered that the indicated flow rate relates to the
unit of measurement of the partial. In the example shown, the flow
rate is expressed in Qts/min.
The word “Gal” remaining alongside the flow rate refers to the re-
gister of the Totals (Reset or NON Reset) which are again displayed
when exiting from the flow rate reading mode.
To return to “Normal” mode, press the MODE key again. If one of the two keys RESET or MODE is
accidentally pressed during the count, this will have no effect.
ATTENTION
Even though in this mode they are not displayed, both the Reset Total
and the General Total (Total) increase. Their value can be checked
after dispensing has terminated, returning to “Normal” mode, by
quickly pressing MODE.
13.7.1 PARTIAL RESET (FLOW RATE MODE)
To reset the Partial Register, finish dispensing and wait for the Remote Dis-
play to show a Flow Rate of 0.0 as indicated in the illustration
then quickly press RESET.