Pittsburgh 92703 Скачать руководство пользователя страница 5

Page 5

For technical questions, please call 1-800-444-3353.

SKU 92703

REV 07h

Maintenance and Servicing

  Procedures not specifically explained 

in this manual must be performed 

only by a qualified technician.

TO PREVENT SERIOUS INJURY 

FROM ACCIDENTAL OPERATION: 

Turn Line Buttons off before performing any 

inspection, maintenance, or cleaning procedures.

TO PREVENT SERIOUS INJURY 

FROM TOOL FAILURE: 

Do not use damaged equipment.  

If abnormal noise or vibration occurs, have 

the problem corrected before further use.

Installing and Removing 

Batteries

1.  Remove the Battery Cover (see Figure 2 

on page 4) and insert two new ‘AA’ Batteries. 

Follow the polarity symbols so that the positive and 

negative ends of the batteries match the diagram. 

2. 

WARNING! 

Do not mix old and new batteries. 

Remove batteries when storing Laser. 

Replacement Parts

NOTE:

 Internal replacement parts are 

not available for this item.

Cleaning and Maintenance

1. 

BEFORE EACH USE,

 inspect the general 

condition Laser Level.  Check for loose 

hardware, misalignment or binding of moving 

parts, cracked or broken parts, and any other 

condition that may affect its safe operation.

2. 

AFTER USE,

 wipe external surfaces 

of the tool with clean cloth.

3.  Store the Laser Level indoors and 

out of children’s reach.

Accuracy Checking

NOTE: 

Due to the complicated, sensitive 

nature of these procedures, ordinarily only a 

qualified technician would attempt them.

Level Beam Accuracy

1.  Set up the instrument with the Tripod centered 

between two walls approximately 16 ft. apart. 

Ensure the Rotary Base is level.

2.  Push the Pendulum Lock to the right to free 

the pendulum.  See Figure 1 on page 3.

3.  Press both the horizontal and vertical buttons to 

project a laser cross on wall A. Mark point 

a

1

 at 

the intersection of the beams. Turn the cross line 

laser 180° and repeat on wall B, marking point 

b

1

 

at the intersection of the beams, see Figure 4.

Figure 4 

4.  Move the instrument straight towards wall A to 

a point 2 ft. away and repeat step 2, marking 

the intersections as 

a

2

 and 

b

2

, see Figure 5.

Figure 5 

5.  a distance (

d

a

)=

|a

1

 -a

2

|

 

b distance (

d

b

)=

|b

1

 -b

2

|

 

If 

|d

a

 - d

b

| <1mm

, the accuracy is within tolerance. 

Otherwise, return the instrument to a qualified 

technician for repair. 

Содержание 92703

Страница 1: ...arborfreight com Email our technical support at tech harborfreight com Copyright 2005 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manual may not be drawn proportionally Due to continuing improvements actual product may dif...

Страница 2: ...m into the eyes of any person or animal Doing so may cause severe eye injury or death 3 Verify Laser Level is in the Off position before making any adjustments or changing the batteries 4 Position batteries in proper polarity and do not install batteries of different types charge levels or capacities together 5 Remove batteries if Laser Level is not to be used for a long period of time 6 The Laser...

Страница 3: ...mation regarding the parts listed in the following pages refer to the Assembly Diagram near the end of this manual 1 Remove the tripod from the case 2 Open tripod s legs and adjust positioning of each leg until base is level Use bubble level in tripod base as a guide 3 Remove the Laser Level from the case 4 Install batteries making sure to align batteries according to indicated polarity 5 Attach t...

Страница 4: ...pening Tri brack one corner Vial Scale Battery Compartment Pendulum Lock hidden 3 Push the Pendulum Lock to the right to free the pendulum See Figure 1 on page 3 4 Press the button for the desired line s on the top of the unit to switch ON Figure 3 Vertical Line Button Horizontal Line Button 5 The Laser Level will work properly if it is positioned within its self leveling range 6 Allow 4 6 seconds...

Страница 5: ...e hardware misalignment or binding of moving parts cracked or broken parts and any other condition that may affect its safe operation 2 AFTER USE wipe external surfaces of the tool with clean cloth 3 Store the Laser Level indoors and out of children s reach Accuracy Checking NOTE Due to the complicated sensitive nature of these procedures ordinarily only a qualified technician would attempt them L...

Страница 6: ... than or equal to 2mm the accuracy is within tolerance Otherwise take the instrument to a qualified technician for repair Vertical Beam Level Accuracy End to End 1 Set up the instrument with the Tripod approximately 16 ft from the wall The wall should be at least 17 ft high Please ensure the Rotary Base is approximately level 2 Press both the horizontal and vertical buttons to project a laser cros...

Страница 7: ...UYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE OR...

Страница 8: ... so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchandise If ...