background image

Page 4

For technical questions, please call 1-800-444-3353.

SKU 92703

REV 05c, 05g, 07h

Operating Instructions

  Read the ENTIRE IMPORTANT 

SAFETY INFORMATION section at the 

beginning of this manual including 

all text under subheadings therein 

before set up or use of this product.

TO PREVENT SERIOUS INJURY 

FROM ACCIDENTAL OPERATION: 

Turn Line Buttons off before adjusting Level.

1.  After removing the Laser from the Carrying 

Case, open the battery compartment, insert the 

two ‘AA’ Batteries into the battery compartment 

according to the polarity symbols shown inside, 

and close the battery compartment door.

2.  Be sure to set the Laser on as flat a surface as 

possible. The tri-brack adjustment on the base 

of the level can be used to help level the unit. 

(Turn each of the knobs to either raise or 

lower that corner.) The self-leveling range of 

the Laser is within ± 6°.  Use the 2 Vials on 

the base to verify that the base is level.

Figure 2 

Laser 

Opening

Tri-brack 

(one corner)

Vial

Scale

Battery 

Compartment

Pendulum 

Lock

(hidden)

3.  Push the Pendulum Lock to the right to free 

the pendulum.  See Figure 1 on page 3.

4.  Press the button for the desired line(s) on 

the top of the unit to switch “ON”.

Figure 3 

Vertical 

Line Button

Horizontal 

Line Button

5.  The Laser Level will work properly if it is 

positioned within its self-leveling range.

6.  Allow 4-6 seconds for the horizontal 

and vertical Laser lines to be stabilized. 

After stabilization, the Laser lines can be used for 

measurement reference. Laser lines may swing 

slightly due to vibration from surroundings.

7.  To prevent damage to the level, tighten the 

pendulum lock (see Figure 1 on page 3) 

after use and store in the carrying case.

NOTICE:  If the pendulum lock is not engaged 

before movement, the level may be damaged.

After Using Laser

1.  Detach Laser from Tripod.

2.  Switch off both laser lines, horizontal and vertical. 

Check to see that both indicator LED’s are off. 

3.  Engage Pendulum Lock by moving it to the left.  

See Figure 1 on page 3.  After use the 

Pendulum Lock should be locked before the 

instrument is put away in the Carrying Case.

Содержание 92703

Страница 1: ...arborfreight com Email our technical support at tech harborfreight com Copyright 2005 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manual may not be drawn proportionally Due to continuing improvements actual product may dif...

Страница 2: ...m into the eyes of any person or animal Doing so may cause severe eye injury or death 3 Verify Laser Level is in the Off position before making any adjustments or changing the batteries 4 Position batteries in proper polarity and do not install batteries of different types charge levels or capacities together 5 Remove batteries if Laser Level is not to be used for a long period of time 6 The Laser...

Страница 3: ...mation regarding the parts listed in the following pages refer to the Assembly Diagram near the end of this manual 1 Remove the tripod from the case 2 Open tripod s legs and adjust positioning of each leg until base is level Use bubble level in tripod base as a guide 3 Remove the Laser Level from the case 4 Install batteries making sure to align batteries according to indicated polarity 5 Attach t...

Страница 4: ...pening Tri brack one corner Vial Scale Battery Compartment Pendulum Lock hidden 3 Push the Pendulum Lock to the right to free the pendulum See Figure 1 on page 3 4 Press the button for the desired line s on the top of the unit to switch ON Figure 3 Vertical Line Button Horizontal Line Button 5 The Laser Level will work properly if it is positioned within its self leveling range 6 Allow 4 6 seconds...

Страница 5: ...e hardware misalignment or binding of moving parts cracked or broken parts and any other condition that may affect its safe operation 2 AFTER USE wipe external surfaces of the tool with clean cloth 3 Store the Laser Level indoors and out of children s reach Accuracy Checking NOTE Due to the complicated sensitive nature of these procedures ordinarily only a qualified technician would attempt them L...

Страница 6: ... than or equal to 2mm the accuracy is within tolerance Otherwise take the instrument to a qualified technician for repair Vertical Beam Level Accuracy End to End 1 Set up the instrument with the Tripod approximately 16 ft from the wall The wall should be at least 17 ft high Please ensure the Rotary Base is approximately level 2 Press both the horizontal and vertical buttons to project a laser cros...

Страница 7: ...UYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE OR...

Страница 8: ... so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchandise If ...

Отзывы: