background image

Page 3

For technical questions, please call 1-800-444-3353.

SKU 92703

Specifications

Laser Range

Projects Up to 40 ft.

Max. Tripod Height

48” 

Self Leveling Range 6°
Batteries

(2) ‘AA’ (included)

WARNING

To prevent serious injury and blindness:  

Do not use included goggles for eye 

protection.  Read manual before use.

LASER LIGHT

AVOID DIRECT EYE EXPOSURE

Max. Output: <5mW,

Wavelength: 650 nm ±10 nm

CLASS IIIa LASER PRODUCT

This product complies with 21 CFR 1040.10 and 1040.11

Diode Mfr.: Sean & Stephen Corp.

4F, NO3, Lane 335, Sec 4, Hsin-Yi Rd., Taipen, China

Manufacture Date: ___________, _______ 

05a-11d

Assembly

  Read the ENTIRE IMPORTANT 

SAFETY INFORMATION section at the 

beginning of this manual including 

all text under subheadings therein 

before set up or use of this product.

TO PREVENT SERIOUS INJURY 

FROM ACCIDENTAL OPERATION: 

Turn Line Buttons off before adjusting Laser Level.

Note:

  For additional information regarding the 

parts listed in the following pages, refer to the 

Assembly Diagram near the end of this manual.

1.  Remove the tripod from the case. 

2.  Open tripod’s legs and adjust positioning 

of each leg until base is level.  Use bubble 

level in tripod base as a guide. 

3.  Remove the Laser Level from the case.

4.  Install batteries, making sure to align 

batteries according to indicated polarity.   

5.  Attach the Laser to the tripod base.  Do this by 

threading the bolt at the top of the tripod through the 

holes at the center of the Laser Level’s lower base.

 

6.  Level the Laser by using the tri-brack 

adjustment screws until the bubbles 

are centered on the two levels.

7.  Push the Pendulum Lock to the right to 

free the pendulum.  See Figure 1.

Figure 1 

Pendulum 

Lock

8.  Turn on the Laser.  Allow the laser lines to 

stabilize for 4 to 6 seconds before starting 

any measuring or leveling tasks.

9.  To disassemble and store, move the 

pendulum lock to the left (see Figure 1) and 

follow the above directions in reverse.

NOTICE:  If the pendulum lock is not engaged 

before movement, the level may be damaged.

REV 10k

Содержание 92703

Страница 1: ...arborfreight com Email our technical support at tech harborfreight com Copyright 2005 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manual may not be drawn proportionally Due to continuing improvements actual product may dif...

Страница 2: ...m into the eyes of any person or animal Doing so may cause severe eye injury or death 3 Verify Laser Level is in the Off position before making any adjustments or changing the batteries 4 Position batteries in proper polarity and do not install batteries of different types charge levels or capacities together 5 Remove batteries if Laser Level is not to be used for a long period of time 6 The Laser...

Страница 3: ...mation regarding the parts listed in the following pages refer to the Assembly Diagram near the end of this manual 1 Remove the tripod from the case 2 Open tripod s legs and adjust positioning of each leg until base is level Use bubble level in tripod base as a guide 3 Remove the Laser Level from the case 4 Install batteries making sure to align batteries according to indicated polarity 5 Attach t...

Страница 4: ...pening Tri brack one corner Vial Scale Battery Compartment Pendulum Lock hidden 3 Push the Pendulum Lock to the right to free the pendulum See Figure 1 on page 3 4 Press the button for the desired line s on the top of the unit to switch ON Figure 3 Vertical Line Button Horizontal Line Button 5 The Laser Level will work properly if it is positioned within its self leveling range 6 Allow 4 6 seconds...

Страница 5: ...e hardware misalignment or binding of moving parts cracked or broken parts and any other condition that may affect its safe operation 2 AFTER USE wipe external surfaces of the tool with clean cloth 3 Store the Laser Level indoors and out of children s reach Accuracy Checking NOTE Due to the complicated sensitive nature of these procedures ordinarily only a qualified technician would attempt them L...

Страница 6: ... than or equal to 2mm the accuracy is within tolerance Otherwise take the instrument to a qualified technician for repair Vertical Beam Level Accuracy End to End 1 Set up the instrument with the Tripod approximately 16 ft from the wall The wall should be at least 17 ft high Please ensure the Rotary Base is approximately level 2 Press both the horizontal and vertical buttons to project a laser cros...

Страница 7: ...UYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE OR...

Страница 8: ... so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchandise If ...

Отзывы: