background image

Page 2

For technical questions, please call 1-888-866-5797.

Item 62707 

        

Specifications 

Blue (Low) Gauge

0-120 PSI

Blue Hose

1

/

4

 IN. FFL x 4 FT. 9 IN.

Red (High) Gauge

0-500 PSI

Red Hose

1

/

4

 IN. FFL x 4 FT. 9 IN.

Yellow Hose

1

/

2

 IN. ACME x 4 FT. 9 IN.

Gauge Accuracy

+/-2%

Set includes Quick Disconnect Valves

WARNING!  ONLY USE R-134a REFRIGERANT WITH THIS A/C MANIFOLD GAUGE SET.

Safety Warnings 

 

WARNING Read all safety warnings and instructions.  

Failure to follow the warnings and instructions may result in serious injury.   

Save all warnings and instructions for future reference.

1. 

Keep work area clean and well lit

.

2. 

Keep children away

.  Children must never 

be allowed in the work area.  Do not let them 
handle the A/C Manifold Gauge Set.

3.  There are certain applications for which this  

A/C Manifold Gauge Set was designed. 
It will do the job better and more safely 
at the rate for which it was intended. 
Do not modify this A/C Manifold Gauge Set 
and do not use this A/C Manifold Gauge Set 
for a purpose for which it was not intended.

4. 

Dress properly

.  Do not wear loose clothing 

or jewelry as they can be caught in moving 
engine parts.  Protective clothes and nonskid 
footwear are recommended when working.  
Wear restrictive hair covering to contain long hair.

5.  Wear ANSI-approved impact safety goggles 

and heavy-duty work gloves at all 
times during setup and use.

6. 

Do not overreach

.   

Keep proper footing and balance at all times. 

7. 

Maintain gauge with care

.  Keep the 

A/C Manifold Gauge Set clean for better and  
safer performance.  Inspect hoses 
periodically, and if damaged, have them 
repaired by a qualified technician. 

8. 

Stay alert

.  Watch what you are doing, 

use common sense. Do not operate 
gauge when you are tired.

9. 

Check for damaged parts

.  Before using any 

gauge, any part that appears damaged should 
be carefully checked to determine that it will 
operate properly and perform its intended function. 
Check for alignment and binding of moving parts; 
any broken parts or mounting fixtures; and any 
other condition that may affect proper operation.  
Any part that is damaged should be properly 
repaired or replaced by a qualified technician.

10. 

Replacement parts and accessories

.   

When servicing, use only identical 
replacement parts.  Use of any other parts will 
void the warranty.  Only use accessories intended 
for use with this gauge.  Approved accessories 
are available from Harbor Freight Tools.

11. 

Do not operate gauge if under the influence of 
alcohol or drugs

.  Read warning labels if taking 

prescription medicine to determine if  
your judgment or reflexes are impaired 
while taking drugs. If there is any 
doubt, do not operate the gauge.

12. 

Maintenance

.  For your safety, 

service and maintenance should be 
performed regularly by a qualified technician.

13. 

Industrial applications must follow  
OSHA requirements.

Содержание 62707

Страница 1: ...ection maintenance and cleaning procedures Write the product s serial number in the back of the manual near the assembly diagram or month and year of purchase if product has no number Keep this manual...

Страница 2: ...avy duty work gloves at all times during setup and use 6 Do not overreach Keep proper footing and balance at all times 7 Maintain gauge with care Keep the A C Manifold Gauge Set clean for better and s...

Страница 3: ...tand all instructions and safety precautions as outlined in the vehicle manufacturer s manual for air condition servicing Only qualified mechanics that are trained in servicing air conditioning system...

Страница 4: ...uation b Charging filling the system c For checking attach the Yellow Hose 13b to both branches of the T fitting 10 to reduce the risk of leaks 7 The charge valve allows for simultaneous connection of...

Страница 5: ...tilated area ONLY Refrigerant can displace air if allowed to accumulate causing sudden loss of consciousness followed by death This can happen WITHOUT FEELING SHORTNESS OF BREATH TO PREVENT EXPLOSION...

Страница 6: ...b Connect one end of the Red Hose 13a to the Red LP Hose Connector and the other end to the Red Coupler 7 c Connect one end of the Yellow Hose 13b to the Yellow Charge Hose Connector 10 and the other...

Страница 7: ...o the Red LP Hose Connector and the other end to the Red Coupler 7 c Connect one end of the Yellow Hose 13b to the Yellow Charge Hose Connector 10 and the other end to the refrigerant recovery system...

Страница 8: ...ose 13a to the Red LP Hose Connector and the other end to the Red Coupler 7 c Connect one end of the Yellow Hose 13b to the Yellow Charge Hose Connector 10 and the other end to refrigerant supply KEEP...

Страница 9: ...corrected before further use 1 Before each use inspect the general condition of the A C Manifold Set Check for cracked or broken parts damaged Hoses 13a 13b 13c and any other condition that may affec...

Страница 10: ...2 10 T Connector 1 11 Red Coupler Storage Plug 1 12 Blue Coupler Storage Plug 1 Part Description Qty 13a Red Hose HP Refrigerant 1 13b Yellow Hose HP Refrigerant 1 13c Blue Hose LP Refrigerant 1 14 Ma...

Страница 11: ...ODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASS...

Страница 12: ...usion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLU...

Отзывы: