Page 7
For technical questions, please call 1-888-866-5797.
Item 62707
WARNING
To prevent SERIOUS INJURY
and DEATH:
1. Wear ANSI-approved safety goggles
and heavy-duty work gloves
during setup and use.
2. DO NOT OPEN either
Manifold Valve unless directed to
do so; otherwise, refrigerant leaks,
A/C system contamination,
and hazardous expulsion of
pressurized refrigerant may occur.
3. Use in well-ventilated area only.
4. Keep gauge and hoses away
from moving engine parts.
5. Turn off vehicle’s engine and
A/C system before attaching gauge.
6. The following procedure is to be
performed only by a technician
certified in refrigerant recovery
and recycling procedures,
as explained previously.
Recovery / Evacuation
1.
Close both Manifold Valves (5,6) by turning CW.
Close both Coupler Valves (7,8) by turning CCW.
2.
CONNECT HOSES:
a. Connect one end of the Blue Hose (13c)
to the Blue LP Hose Connector and the
other end to the Blue Coupler (8).
b. Connect one end of the Red Hose (13a)
to the Red LP Hose Connector and the
other end to the Red Coupler (7).
c. Connect one end of the Yellow Hose (13b)
to the Yellow Charge Hose Connector (10)
and the other end to the refrigerant
recovery system / vacuum pump.
3.
ATTACH COUPLERS:
a. Attach the Blue Coupler (8) to the
suction LP port on the A/C system.
b. Attach the Red Coupler (7) to the
discharge HP port on the A/C system.
4.
PERFORM RECOVERY / EVACUATION:
a. Turn on the refrigerant recovery
system / vacuum pump.
b. Open both Coupler Valves (7,8) by turning CW
and both Manifold Valves (5,6), turning them CCW.
c. Read the amount of vacuum on
the Blue LP Gauge (3).
5.
AFTER:
a. Shut off the refrigerant recovery system /
vacuum pump when the vacuum level reaches
the manufacturer’s recommended level.
b.
Close both Coupler Valves (7,8)
by turning CCW.
c. Disconnect the Couplers (7,8)
from the A/C system. Pull back the knurled
ring on each Coupler (7,8) and store it
on its Coupler Storage Plug (11,12).
To
discharge
HP port
To refrigerant
recovery system
/ vacuum pump
To
suction
LP port
CCW
CCW
CW
CW
TURN VALVES AS SHOWN ONLY AFTER MAKING ALL
CONNECTIONS AND TURNING ON REFRIGERANT
RECOVERY SYSTEM / VACUUM PUMP
Blue
Blue
Yellow
Yellow
Red
Red