4     OPERATING PRINCIPLE 

 
COMPONENTS 
 

• 

LOUVERS: 

Louvers are discharge air deflectors, either adjustable or nonadjustable, that 

change or route the air flow 
 
• 

HEATING COIL

: convert electrical energy to heat by passing electrical current through a 

specifically designed resistance wire. Constructed of spiral wound resistance wire, surrounded 
by an insulating power , encased in a metal enclosure. Either Monophase or Threephase 
types can be provided upon by request. 
 
• 

FAN (FAN BLADE): 

is a propeller type device, used to move the air through the unit heater. 

Unit heaters discussed in this manual are directly coupled to an electric motor. They are not 
belt driven. 
 
• 

MOTOR

:are permanently lubricated electrical devices that rotate the fan to move the heated 

air from the heater to the space. When the unit heater wattage is over loaded one or more 
CONTACTORS are employed to switch the electrical current to the elements and / or 
the motor. Usually a thermostat or fan delay will control when the contactor is energized. 
 
• 

OVER TEMPERATURE LIMIT: 

is a normally closed  temperature sensing device, located on 

or in close proximity to the element, designed into the heater to open  f an abnormally hot 
condition occurs. Abnormally hot conditions are usually the result of a loss of moving air 
across the element. Frequent causes of over temperature limit opening are; blocked inlet or 
discharge, motor stoppage and loose fan. 
 

5   APPLICATION AND INTENDED USE 

The units are designed for heating air in closed areas. Heaters can be mounted for horizontal 
or vertical air flow. 
 
Typical Application Areas: 

  Factories 

  Warehouses 

  Garages 

  Stores 

  Power Stations and Aircraft Hangers 

  Agricultural Barns 

  Green Houses 

  Industrial assembly areas 

  Enclosed outside smoking areas. 

 

Wall type or ceiling mounting bracket for horizontal  or vertical air flow or any position 

between. 

 

 

Содержание EKI 400x200-10.5-3/3x3.5 kw

Страница 1: ...senyurt Yolu zeri No 66 68 Ba lar Mevkii TR 34850 Avc lar STANBUL Tel 0212 4281885 Fax 0212 4281661 Email pitsan pitsan com http www pitsan com INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS ELECTRIC...

Страница 2: ...n com CONTENTS 1 GENERAL 3 2 SAFETY 3 2 1 Safety instructions 3 2 2 Correct use 3 3 DESCRIPTION OF THE UNIT 5 4 OPERATING PRINCIPLE 7 5 APPLICATION AND INTENDED USE 7 6 PACKAGING HANDLING STORAGE 8 7...

Страница 3: ...ccordance with local electrical codes This equipment requires a ground as precaution against electrical shock Basic precautions should always be followed to reduce the risk of fire electric shock and...

Страница 4: ...working properly in threephase models Hot Furface The surface temperature of the heater may rise up to temperatures which will cause inquiry Do not touch the surface while the heater is operating In...

Страница 5: ...PITSAN Page 5 16 P TSAN MAK SAN VE T C LTD T Esenyurt Yolu zeri No 66 68 Ba lar Mevkii TR 34850 Avc lar STANBUL Tel 0212 4281885 Fax 0212 4281661 Email pitsan pitsan com http www pitsan com 3 DESCRIPT...

Страница 6: ...ater Units PITSAN Page 6 16 P TSAN MAK SAN VE T C LTD T Esenyurt Yolu zeri No 66 68 Ba lar Mevkii TR 34850 Avc lar STANBUL Tel 0212 4281885 Fax 0212 4281661 Email pitsan pitsan com http www pitsan com...

Страница 7: ...evices that rotate the fan to move the heated air from the heater to the space When the unit heater wattage is over loaded one or more CONTACTORS are employed to switch the electrical current to the e...

Страница 8: ...ents on pallets It is essential that great care is exercised when handling the unit When handling the equipment care should be taken with corners and edges and that the weight distribution within the...

Страница 9: ...imum recommended mounting height to bottom of heater 4 5meters Minimum clearance from walls and ceiling are Z 250mm VERTICAL DISCHARGE To ensure proper heating of floor surfaces observe the following...

Страница 10: ...ctrical Heater Units PITSAN Page 10 16 P TSAN MAK SAN VE T C LTD T Esenyurt Yolu zeri No 66 68 Ba lar Mevkii TR 34850 Avc lar STANBUL Tel 0212 4281885 Fax 0212 4281661 Email pitsan pitsan com http www...

Страница 11: ...ctrical Heater Units PITSAN Page 11 16 P TSAN MAK SAN VE T C LTD T Esenyurt Yolu zeri No 66 68 Ba lar Mevkii TR 34850 Avc lar STANBUL Tel 0212 4281885 Fax 0212 4281661 Email pitsan pitsan com http www...

Страница 12: ...gh limits of the motor and or heater 9 Check out and repost any unusual or questionable operating characteristics such as noise vibration etc 10 Set the fan switch and temperature control on desired o...

Страница 13: ...lectrical cable insulations contactors to avoid any short circuits Be sure that all clearances for air intake are kept as installation 10 POSSIBLE PROBLEM CAUSES AND SOLUTIONS PROBLEM POSSIBLE CAUSE S...

Страница 14: ...ate of normal service when installed and operated in accordance with the instructions provided by the Company and subject to the following conditions 1 Since the paint finish may be damaged in use no...

Страница 15: ...212 4281885 Fax 0212 4281661 Email pitsan pitsan com http www pitsan com 12 APPENDIX The customers confirm by their signatures that they have received read and understood the operating and maintenance...

Страница 16: ...t to internal manufacturing checks with monitoring of the final assesment by PITSAN MACHINE MODEL LIST ETA EKI series electrical heating units APPLICABLE DIRECTIVES 2006 42 EC MACHINERY SAFETY DIRECTI...

Отзывы: