background image

Advanced Installation Requirements

If you have extensive network security restrictions, your IT or network administrator may need these
specifications to prepare for the install.

l

Wi-Fi connectivity specifications

l

Port and communication requirements

l

Required URL information

l

Recommended URL information

l

File extension requirements

Wi-Fi Connectivity Specifications

If you purchase a network connection via a Wi-Fi connectivity device, your IT or network administrator
may need these specifications.

l

Mode - Client Mode

l

Standards - IEEE 802.11n, 802.11b, 802.11g (802.1X networks are not supported)

l

Protocols - TCP/IP, PPPoE, DHCP, ICMP, NAT, SNTP

l

Safety and Emissions - FCC, CE

l

Frequency Band - 2.4~2.4835GHz

l

Radio Data Rate - 11n

up to 150Mbps (Automatic); 11g

54/48/36/24/18/12/9/6M (Automatic);

11b

11/5.5/2/1M (Automatic)

l

Frequency Expansion - DSSS(Direct Sequence Spread Spectrum)

l

Modulation - DBPSK, DQPSK, CCK, 16-QAM, 64-QAM, BPSK, QPSK

l

Security - 64/128/152-bit WEP, WPA/WPA2, WPA2-PSK/WPAPSK

l

Sensitivity @PER - 135M: -70dBm@10% PER 65M: -73dBm@10% PER; 54M: -76dBm@10%
PER 6M: -92dBm@10% PER

Pitney Bowes

Installation Requirements

March, 2017

Page 3 of 7

Содержание SendPro 300

Страница 1: ...rements SV63248 RevB March 27 2017 Shipping Mailing Postage Meters SendPro 300 Installation Requirements and Connectivity Setup Guide Introduction 2 Basic Installation Requirements 2 Advanced Installation Requirements 3 ...

Страница 2: ...In most cases you connect your meter as described in the instructions included in the box This results in a reliable and secure connection Refer to the Installation Setup Instructions included in the box Power Outlet Requirements The standard system requires a minimum of two electric outlets and up to four electric outlets depending on options purchased l Meter two electric outlets l Meter and Lab...

Страница 3: ...ministrator may need these specifications l Mode Client Mode l Standards IEEE 802 11n 802 11b 802 11g 802 1X networks are not supported l Protocols TCP IP PPPoE DHCP ICMP NAT SNTP l Safety and Emissions FCC CE l Frequency Band 2 4 2 4835GHz l Radio Data Rate 11n up to 150Mbps Automatic 11g 54 48 36 24 18 12 9 6M Automatic 11b 11 5 5 2 1M Automatic l Frequency Expansion DSSS Direct Sequence Spread ...

Страница 4: ...s 31314 993 or 443 using TCP l Ports used for upgrades port 80 using TCP HTTP l Transfer data via HTTPS with TLS 1 2 l Access TeamViewer recommended but not required Proxy and IP Information l Proxy server is not supported l IP o DHCP Dynamic IP is the default o Static IP may be used with assistance from the Pitney Bowes Call Center Have the following information ready for static IP setup n IP add...

Страница 5: ...ailing Application Welcome and Agent servers o imp sl pb com o agent sl pb com l SendPro Shipping Application o https sending us pitneybowes com Domain www pitneybowes com IP 199 231 33 6 199 231 44 12 l Online Help o http support pb com help_videos SV63216 help default htm Domain www pb com Pitney Bowes Installation Requirements March 2017 Page 5 of 7 ...

Страница 6: ...refore there is no security risk This traffic should not be filtered nor cached l Unblock URLs with these formats to any server o GET din aspx s client DynGate o GET dout aspx s client DynGate o POST dout aspx s client DynGate Note Once you unblock TeamViewer verify there are no content filters blocking one of these URLs l teamviewer com l dyngate com Your Account pitneybowes com The meter uses th...

Страница 7: ...uses these file extensions and they must be allowed through your network or firewall or your system will not work l DEC dcz l EMD zmd l Graphics bin l Rate Manager rmz l CCD bin l Snippet file arc Pitney Bowes Installation Requirements March 2017 Page 7 of 7 ...