6-12
SDT3233A DI380/DI425/SI3300/SI3500 Service Manual
6 • OMR
Basic OMR uses only group 1. Enhanced OMR uses group the Group 1 plus Group 2 and / or
Group3. Always include the Group 1 in an OMR code. You may include either or both of the second
and third groups if these features are needed for a particular job. If the Auto-Batch function is used,
the mark must appear on each sheet of the last set of a batch printed in reverse-collation, and on the
first set of a batch printed in forward-collation.
6.16 eNABLING THe OMR FeATURes
6.16.1 Basic OMR
To enable the Basic OMR option:
1. Open the hinged cover to the right of the OMR display.
2. Press the
change
button (+/-) to enter Access Code 17.
3. Press the
Next
( ► ) button until the option Set Parameters appears, then press the Start button.
4. Press the
Next
( ► ) button until the option Select OMR Basic Mode appears, then press the
Start button.
5. The display shows OMR Basic Mode Is OFF. Press the
change
(+/-) button until the display
shows OMR Basic Mode is ON. Press the
stop
button. This enables Basic OMR.
6. Exit Set Parameters per your usual procedures.
6.16.2 enhanced OMR
Enhanced OMR includes the Basic OMR features plus selective feed, auto-batch and wrap-around
sequencing (WAS). These Enhanced features are not accessible and are not displayed in menus for
OMR machines configured for Basic OMR.
If the customer has purchased the Enhanced OMR option, the Pitney Bowes Service Representa-
tive enables the full set of OMR features through the Service Setup menu by entering the passcode
350350
when prompted.
Do NOT give this passcode to the customer.
To enable the Enhanced OMR option:
1. Open the hinged cover to the right of the OMR display.
2. Press the
change
button (+/-) to enter Access Code 17.
3. Press the
Next
( ►) button until the option Set Parameters appears, then press the
start
button.
4. Press the
Next
( ►) button until the option Set Enhanced OMR Mode appears, then press the
start
button.
5. The display indicates Count: 0. Press the
change
button (+/-) until the count reads
350350
. This
is the code that enables Enhanced OMR. Press the
start
button. The display shows Enhanced OMR
Mode Is ON.
6. Exit
Set Parameters
per your usual procedures.
6.16.3 switching Off OMR
To switch off enhanced OMR:
1. Open the hinged cover to the right of the OMR display.
2. Press the
change
button (+/-) to enter Access Code 17.
3. Press the
Next
( ►) button until the option Set Parameters appears, then press the
start
button.
4. Press the
Next
( ►) button until the option Set Basic OMR Mode appears, then press the
start
button.
5. The display shows OMR Basic Mode Is OFF. Press the
change
(+/-) button until the display
shows OMR Basic Mode is ON. Press the
stop
button. This enables Basic OMR.
6. Exit Set Parameters per your usual procedures.
7. Both Basic and Enhanced OMR will now be switched Off.
Содержание DI380 Series
Страница 32: ...3 18 SDT333A DI380 DI425 SI3300 SI3500 Service Manual 3 Theory of Operation ...
Страница 50: ...4 18 SDT333A DI380 DI425 SI3300 SI3500 Service Manual 4 Removal Replacement ...
Страница 66: ...5 16 SDT333A DI380 DI425 SI3300 SI3500 Service Manual 5 Adjustments ...
Страница 102: ...7 22 SDT333A DI380 DI425 SI3300 SI3500 Service Manual 7 Service Menu Troubleshooting ...
Страница 114: ...10 8 SDT333A DI380 DI425 SI3300 SI3500 Service Manual 10 Diagrams 10 5 drive belt routing Rear View Front View ...
Страница 122: ......