WARNING 

This appliance is equipped with a three prong 

(grounding) plug. This is for your protection against 

shock hazard in the event of equipment malfunction. 

Always plug the unit directly into a properly grounded 

three-prong receptacle. DO NOT cut or remove the 

grounding (third) prong. 

 

WARNING 

DO NOT use an open flame to check for gas leaks! 

Keep all open flames away from the Rethermalizer 

until the installation is complete. 

 

WARNING 

A Rethermalizer equipped with casters and a flexible 

power cord, must be connected to the gas supply with 

a Quick-Disconnect device. This quick disconnect 

must comply with ANSI Z24.41. To limit the 

movement of the unit without depending on the 

connector or quick disconnect, a re straining cable 

must also be installed. 

 

WARNING 

There is an open gas flame inside the Rethermalizer. 

The unit may get hot enough to set nearby materials 

on fire. Keep the area around the unit free from 

combustibles. 

 

WARNING 

Ensure that the Rethermalizer can get enough air to 

keep the flame burning correctly. If the flame is 

starved for air it can give off a dangerous carbon 

monoxide gas. Carbon Monoxide is a clear odor-less 

gas that can cause suffocation. 

 

WARNING 

Carbon monoxide can build up if you block the flue. 

Blocking the flue will also cause the unit to overheat. 
DO NOT obstruct the flow of combustion/ventilation 

or air opening around the Rethermalizer. Ensure that 

you meet the minimum clearances specified in the 

installation instructions. Adequate clearance around 
the unit is necessary for servicing and proper burner 

operation. 

 

WARNING 

Wait 5 minutes before attempting to relight the pilot. 

This will allow for any gas in the unit to dissipate. 

 

WARNING 

The power supply must be disconnected before 

servicing or cleaning the appliance. 

 

WARNING 

The Rethermalizer must be properly restrained to 

prevent movement or tipping. This restraint must 

prevent the unit from movements that would splash hot 

liquids on personnel. This restraint may be by any 

means (alcove installation, adequate ties, or battery 

installation). 

 

WARNING 

DO NOT obstruct the flow of combustion/ventilation 

or air openings around the rethermalizer. Adequate 

clearance around the rethermalizer is necessary for 

servicing and proper burner operation. Ensure that you 

meet the minimum clearances specified in the 

installation instructions. 

 

WARNING 

NEVER supply the Rethermalizer with a gas that is not 

indicated on the data plate. Using the incorrect gas type 

will cause improper operation. If you need to convert 

the unit to another type of fuel, contact your dealer. 

 

WARNING 

In the event of a fire, use ONLY a dry chemical 

extinguisher. The extinguisher should be a B/C or 

A/B/C type extinguisher that contains sodium 

bicarbonate or potassium bicarbonate. 

THIS MANUAL MUST BE 
RETAINED FOR FUTURE 
REFERENCE 

Содержание RTE14

Страница 1: ...Installation and Operation Manual for the Gas and Electric Rethermalizer Model Numbers RTG14 18 RTE14 L20 144 Rev 6 Rev Date 01 98...

Страница 2: ...and heed the notices throughout this manual The WARNINGS are listed below and on the following page for your review prior to operating the unit FOR YOUR SAFETY DO NOT store or use gasoline or other f...

Страница 3: ...truct the flow of combustion ventilation or air opening around the Rethermalizer Ensure that you meet the minimum clearances specified in the installation instructions Adequate clearance around the un...

Страница 4: ...the Rethermalizer 6 Pilot Light System Gas machines with Electronic Ignition Pilot only 6 Pilot Light System Gas machines with Standing Pilot only 7 Main Burner System Gas machines only 8 Initial Cle...

Страница 5: ...a safe place for future reference Checking your new Rethermalizer Every effort has been made to ensure that your Rethermalizer will be delivered to you in perfect condition As you unpack the Rethermal...

Страница 6: ...ine c Mount the bolts from the inside of the unit with the nut on the outside of the cooker The nuts have lock washers attached to them therefore it is not necessary to use lock washers d When all fou...

Страница 7: ...n NOTICE NEVER use an adaptor to make a smaller gas supply line fit the cooker connection This may not allow proper gas flow for optimum burner operation resulting in poor cooker performance Quick Dis...

Страница 8: ...be plugged into a wall receptacle supplied from the ventilation control This will ensure that the Rethermalizer can not be operated unless the ventilator is also on to provide proper ventilation Disc...

Страница 9: ...atest Edition Filter Unit ANSI UL 5 86 Latest Edition ANSI NFPA 96 Latest Edition ANSI UL 900 Latest Edition Types of Fire Extinguishers and Detection Equipment CO2 ANSI UL 154 Latest Edition ANSI NFP...

Страница 10: ...thermalizer is equipped with an automatic water level maintaining system To fill the unit with water press the key This causes the solenoid valve to open and supply water to the unit through the fill...

Страница 11: ...will need to purge the air form the system e Press the key The electronic control unit will come on and display the temperature of the water There will also be a red light lit between the left and mi...

Страница 12: ...the flame and the millivolt output Turning the screw counterclockwise increases flame size and millivolt output g Rotate the screw in the direction to achieve a reading of 400 50 mV NOTE Allow 3 to 5...

Страница 13: ...er f To remove the pressure gauge press the key for Digital controls or the ON OFF switch for computer controls Turn the gas valve knob to PILOT or OFF Remove the gauge and install the pressure tap pl...

Страница 14: ...inue to rinse the tank until the cleaner has been rinsed from the tank e Now that the tank is clean you are ready to fill and operate the Rethermalizer High Limit Switch Gas machines The High Limit sw...

Страница 15: ...olenoid valve open the valve in the bypass pipe This should only be done if the solenoid valve fails and the Rethermalizer needs to be operated When finished filling the Rethermalizer ensure that the...

Страница 16: ...to turn the gas valve clockwise to the OFF position Gas machines with Electronic Ignition pilots These machines can only be shut down to a COMPLETE condition Press the key to turn the Digital control...

Страница 17: ...fic cooking needs Follow the instructions below for the desired changes To enter the programming mode press the key and then release it press the key again and hold it for 5 seconds Setting the operat...

Страница 18: ...Hours Minutes and Seconds The cook time is displayed by depressing the Product Key ONE time The COOK time can be cancelled by depressing the Product Key THREE times Temperature The water temperature...

Страница 19: ...he key two times at any point during this procedure will return you to the normal cook mode Level 2 Programming There are several features that merit mention at this point Their programming functions...

Страница 20: ...t be disconnected before servicing or cleaning the appliance CAUTION Do NOT use chlorine based cleaning agents in your tank the chlorine will attack the metal and lead to premature failure Your Rether...

Страница 21: ...oker cooled down check for corrosion or blockage of the flue and erosion of the baffles Ensure that the cooker is shutdown and do not turn it on during the examination WARNING Examination of the flue...

Страница 22: ...18...

Страница 23: ...19...

Отзывы: