9 . In installing vacuum pad holders of general and small type with bulkhead, check the
structure and tighten the hexagonal-column of the holder with a proper tool, referring to
the following tightening torque.
Vacuum pad holder
Standard
Small
Holder type
VPA
VPC, VPD,
VPF,
VPHC,
VPHD,
VPHDW
VPE
VPMA
VPMC,
VPMD
VPME
Bulkhead nut size
(㎜)
Tightening torque
(
N·m
)
M3×0.5
—
—
0.7
—
—
0.7
M4×0.5
—
—
—
1 ~ 1.2
—
—
M4×0.7
1 ~ 1.2
—
—
—
—
—
M5×0.5
1.5 ~ 2
—
—
1.5 ~ 2
—
—
M5×0.8
—
—
1 ~ 1.5
—
—
1 ~ 1.5
M6×0.75
2 ~ 3
—
—
2 ~ 3
—
M8×0.75
2.5 ~ 3.5
1.8 ~ 2.4
—
2.5 ~ 3.5
—
M8×1
—
1.8 ~ 2.4
—
—
—
—
M10×1
5 ~ 7
4.5 ~ 6
—
5 ~ 7
4 ~ 6
—
M12×1
12 ~ 14
8 ~ 10
—
—
—
—
M14×1
18 ~ 21
4.5 ~ 6
—
—
—
—
M16×1
—
2 ~ 3
—
—
—
—
M20×1
19 ~ 21
—
—
—
—
—
M22×1
—
16 ~ 20
—
—
—
—
M24×2
40 ~ 50
—
—
—
—
—
M30×2
—
42 ~ 54
—
—
—
—
10. In replacing vacuum pad rubbers of Standard Series
ø
80,
ø
100mm,
ø
150mm,
ø
200mm
and Bellows Series
ø
80mm,
ø
100mm, check the structure of holders and pads and
tighten the hexagonal-column of the holder with a proper tool, referring to the following
tightening torque.
●Table. Tightening torque
Screw size
(㎜)
Tightening torque
(
N·m
)
M4×0.7
0.5 ~ 0.7
M5×0.8
11.
12.
13.
14.
15.
Check the structure of vacuum pad in the catalog before replacing a filter element.
Refer to “Common Safety Instructions for Fittings” for handing fitting joint
parts.
In installing spring-holder type, do not hold the shaft A with a spanner.
In replacing vacuum pad, hold the hexagonal-column of the shaft with a
spanner. If the keyway B is deformed, there is a possibility of malfunction.
Excessive tightening of a fixing nut may deform the bulkhead part and B
result in malfunction of the keyway.
As the nature of rubber, powdery component like additives may come out
on the surface of a vacuum pad as time elapses.
A
}
www.p
isco.co
m