■ How to insert and disconnect
1. How to insert and disconnect tubes
①
Tube insertion
Insert a tube into Push-In Fitting of the vacuum generator VG up to the tube
end. Lock-claws bite the tube to fix it and the elastic sleeve seals around the
tube.
Refer to
“
2. Instructions for Tube Insertion
”
under
“
Common Safety Instructions
for Fittings
”
.
②
Tube disconnection
The tube is disconnected by pushing release-ring to release Lock-claws.
Make sure to stop air supply before the tube disconnection.
2. How to fix the product
In order to fix the vacuum generator VG, tighten M3 threads
through the fixing holes on the resin body with tightening
torque 0.3 to 0.35Nm. Refer to the outer dimensional