PISCO Air preparation Series Скачать руководство пользователя страница 7

17

Safety Instructions

 

SAFETY Instructions

 Warning

 This  safety  instructions  aim  to  prevent  personal  injury  and  damage  to 
properties by requiring proper use of PISCO products.
 Be certain to follow ISO 4414 and JIS B 8370

ISO 4414:Pneumatic fluid power…Recomendations for the application of equipment 

to transmission and control systems.

JIS B 8370:General rules and safety requirements for systems and their components.

This safety instructions is classified into “Danger”, “Warning” and “Caution” depending on 

the degree of danger or damages caused by improper use of PISCO products.

1. Selection of pneumatic products

①  A user who is a pneumatic system designer or has sufficient experience 

and technical expertise should select PISCO products.

② Due to wide variety of operating conditions and applications for PISCO 

products,  carry  out  the  analysis  and  evaluation  on  PISCO  products. 
The pneumatic system designer is solely responsible for assuring that 
the  user's  requirements  are  met  and  that  the  application  presents  no 
health or safety hazards.  All designers are required to fully understand 
the specifications of PISCO products and constitute all systems based 
on the latest catalog or information, considering any malfunctions.

2. Handle the pneumatic equipment with enough knowledge and experience

①  Improper  use  of  compressed  air  is  dangerous.  Assembly,  operation 

and  maintenance  of  machines  using  pneumatic  equipment  should  be 
conducted by a person with enough knowledge and experience.

3. Do not operate machine / equipment or remove pneumatic equipment until 

safety is confirmed.
①  Make  sure  that  preventive  measures  against  falling  work-pieces  or 

sudden  movements  of  machine  are  completed  before  inspection  or 
maintenance of these machine.

②  Make  sure  the  above  preventive  measures  are  completed.  A 

compressed  air  supply  and  the  power  supply  to  the  machine  must  be 
off, and also the compressed air in the systems must be exhausted.

③  Restart  the  machines  with  care  after  ensuring  to  take  all  preventive 

measures against sudden movements.

 

Danger

Hazardous  conditions.  It  can  cause  death  or  serious 

personal injury.

 

Warning

Hazardous conditions depending on usages. Improper use of 

PISCO products can cause death or serious personal injury.

 

Caution

Hazardous conditions depending on usages. Improper use of PISCO 

products can cause personal injury or damages to properties.

. This safety instructions are subject to change without notice.

Содержание Air preparation Series

Страница 1: ...egative Pressure Union Filter Keeping the same usability with vacuum filter VFU Series and usable with positive pressure Suitable as pre filter in positive pressure system Element can be replaced without any tool easy maintenance Positive Negative Pressure Union Filter of Copper alloy free specification is available for the field requiring No copper alloy and Low level ozone resistance Copper allo...

Страница 2: ...s used in other temperature range refer to Chart of Operationg Temperature Max Operationg Pressure below 2 When the filter is operated under a high temperature due to an adiabatic compression refer to Chart of Operationg Temperature Max Operationg Pressure and use the producut under the condition where the environmental and product temperature shall not be exceeded operating temperature Holder Hol...

Страница 3: ...and an excessive force on products Otherwise there is a risk of damaging to products 3 The filter s clear cover is made of PCTG Avoid using the product under the einvironment where the following chemical substance is contained in the ambient air or either felt in the air or the chemical substance can attach to the filter itself Table Chemical list Chemical Name Thinner Cyclohexane Carbon tetrachlor...

Страница 4: ...fore the tube disconnection 2 How to tighten screw Tightening screw Use two fixing holes on the holder and the following screws to fix the product Refer to the dimensional drawings of the hole pitch Fixing screws for SFU1 M3 countersunk screw and for M4 screw Figure in case of SFU2 3 Caution 1 Before connecting the tubes and installing the filter make sure of the air flow direction The specified perf...

Страница 5: ...e Union Filter SFU compliant 2 C 4 L9 OUT IN L8 L7 B2 L6 L5 B1 L3 L4 2 Y øP1 2 øD 2 X T L1 L2 Fixing holes for M3 countersunk screw OUT IN 2 C L6 L5 L4 4 L9 L8 L3 L7 B2 B1 øP1 L2 L1 T 2 øP2 2 øD 2 ø4 5 SFU1 SFU2 3 CAD CAD 3D 0 0 0 02 0 04 0 06 0 08 0 10 0 12 40 60 20 80 100120140160180200 SFU1 44 Pressure Drop Amount MPa Flow Rate l min ANR 0 0 0 02 0 04 0 06 0 08 0 10 0 12 50 100 150 200 300 250 ...

Страница 6: ...ide of the filter cover by air blowing Place a filter on the joint part of filter element Insert the fitting part and turn it clockwise until it stops Make sure the lock position arrow on the fitting part and that on the filter cover meet face to face then push up the slide lock to the arrowed direction Check if the fitting part is fixed on the filter cover properly Joint Part of Filter Element Filter Elem...

Страница 7: ...f PISCO products and constitute all systems based on the latest catalog or information considering any malfunctions 2 Handle the pneumatic equipment with enough knowledge and experience Improper use of compressed air is dangerous Assembly operation and maintenance of machines using pneumatic equipment should be conducted by a person with enough knowledge and experience 3 Do not operate machine equ...

Страница 8: ...hird parties and intentional or accidental damages of PISCO products due to incorrect usage 3 PISCO does not take any responsibility for any loss caused by improper usage of PISCO products such as exceeding the specification limit or not following the usage the published instructions and catalog allow 4 PISCO does not take any responsibility for any loss caused by remodeling of PISCO products or b...

Страница 9: ...cuit Rotary Block only The other PISCO products can be damaged in these applications 8 Use only Die Temperature Control Fitting Series Tube Fitting Stainless SUS316 Series Tube Fitting Stainless SUS316 Compression Fitting Series or Tube Fitting Brass Series under the condition of over 60 140 F water or thermal oil Other PISCO products can be damaged by heat and hydrolysis under the condition above...

Страница 10: ... mm size Nylon tube Polyurethane tube inch size Nylon tube Polyurethane tube ø1 8mm 0 05mm ø1 8 0 1mm 0 15mm ø3mm 0 15mm ø5 32 0 1mm 0 15mm ø4mm 0 1mm 0 15mm ø3 16 0 1mm 0 15mm ø6mm 0 1mm 0 15mm ø1 4 0 1mm 0 15mm ø8mm 0 1mm 0 15mm ø5 16 0 1mm 0 15mm ø10mm 0 1mm 0 15mm ø3 8 0 1mm 0 15mm ø12mm 0 1mm 0 15mm ø1 2 0 1mm 0 15mm ø16mm 0 1mm 0 15mm ø5 8 0 1mm 0 15mm 6 Instructions for Tube Insertion Make ...

Страница 11: ...d thread or a fluid leakage Adjust the tube direction while tightening thread within these limits since some PISCO products are not rotatable after the installation Table 2 Recommended tightening torque Sealock color Gasket materials Thread type Thread size Tightening torque Sealock color Gasket materials Metric thread M3 0 5 0 7N m SUS304 NBR M5 0 8 1 0 1 5N m M6 1 2 2 7N m M3 0 5 0 5 0 6N m POM ...

Страница 12: ...o products 3 Implement periodic maintenances for the filter element There is a risk of impairing the performance or causing troubles by the clogging Thoroughly read and understand the instructions of replacing elements or removing dust in this catalog Make sure to release the residual pressure completely in the system before the maintenance Caution 1 Refer to Common Safety Instructions for Fitting...

Отзывы: