■ How to insert and disconnect
1. How to insert and disconnect tubes
①
Tube installation
For Positive-Negative Pressure Union Filter (Filter with a built-in tube fitting
inside), insert a Push-In Fitting until it touches to the tube end which makes the
lock-claws bite the tube to fix and the elastic sleeve seal around the tube.
Refer to
“
2. Instructions for Tube Installation
”
under
“
Common Safety
Instructions for Fittings
”
when installing a tube fitting.
②
Tube disconnection
The tube is disconnected by pushing the release-ring which releases the lock-
claws.
Make sure to stop air supply before the tube disconnection.
2. How to tighten screw
①
Tightening screw
Use two fixing holes on the holder and the following screws to fix the product.
(Refer to the dimensional drawings of the hole pitch)
Fixing screws for SFU1: M3 countersunk screw and for
▲
M4 screw
(Figure in case of SFU2&3)
Caution
1. Before connecting the tubes and installing the filter, make sure of the air flow direction. The specified
performance cannot be attained if the filter is placed in the wrong direction.
2. Make sure that the casing is properly fixed and there is no leak after the dust is removed and/or the
element is replaced.
3. When used in a circuit where the vacuum and the vacuum breaking air is interchangeably applied, extra
attention is required since the dust removed by the filter element can be discharged by the vacuum
breaking air.
4. Make sure that the O-ring is not damaged at each overhauling or reassembly. Using a damaged O-ring
can cause leak and/or other function failure.