53
PLAYA - USE AND MAINTENANCE
DISPLAYED
MESSAGE
ACTIONS TAKEN
FROM THE
CONTROL SYSTEM
ITEM THAT
GENERATED THE
ALARM
POSSIBLE
CAUSES
RECOVERY MODE
FLC
if turned on,
heater is
switched off
the flow switch
detects the
flow even with
the filtration
pump turned
off
flow switch
blocked or
defective
Replacement of the
switch, the alarm
is reset by pressing
the on-off button
no alarm, but
the pool warms
slightly
a LED flashes in
the lower right
on the display
when the heater
is in operation.
If the LED is
off, despite the
set temperature
is higher than
water, it means
that we are in
a transitional
phase of pre-
clogging and
the heater was
turned off
the flow
switch is in an
intermediate
stage on / off
semi-clogged
filter
Clean the filter
no alarm, but
the pool warms
slightly
a LED flashes
in the lower
right on the
display
--
lack of
isotherm
cover, setting
the filtration
cycles (the
heater turns on
only when the
filter pump is
running)
use the isotherm
cover, the filter
pump has to
operate 24 hours
no alarm, but
the pool warms
slightly
a LED flashes
in the lower
right on the
display
--
the protection
fuse output of
the heater is
interrupted,
the protection
tab of the
heater is
broken
replace fuse,
check heater
protection tab,
replace heater
Содержание PLAYA 1
Страница 2: ...2 PLAYA USO E MANUTENZIONE ...
Страница 3: ...3 PLAYA USO E MANUTENZIONE GENERAL INDEX pag 4 pag 34 pag 60 pag 86 pag 112 17 GIU ...
Страница 137: ...137 PLAYA USO E MANUTENZIONE NOTE ...
Страница 138: ...138 PLAYA USO E MANUTENZIONE NOTE ...
Страница 139: ...139 PLAYA USO E MANUTENZIONE NOTE ...
Страница 140: ...140 PLAYA USO E MANUTENZIONE NOTE ...
Страница 144: ...GARANZIA ITALIA ...