Manual Revision: June 20
Copyright © 2013-2020 Pirate Brand®, All Rights Reserved
12
C-Series Jr - 0.5 / 1.0
Cu Ft
User’s Manual
Maintenance Procedures
WARNING
: Maintenance procedures are to be performed by experienced qualified personnel only. Failure to
perform maintenance procedures correctly at the intervals specified below can lead to performance problems
and equipment failure, and will void the equipment warranty.
DANGER
: Never perform any maintenance or attempt to open the Abrasive Blaster in any way while it is
pressurized. The violent release of compressed air and propelled objects will cause serious injury or death.
Descriptions of maintenance procedures referenced in this table are located on the next page.
Procedure To Be Performed
Maintenance Interval
1 - Inspect Personal Protective Equipment (PPE)
Every 8 Hours Of Use
Including but not limited to: Respirators, Airline Filters, Carbon-Monoxide Monitors,
Hearing Protection, Eye Protection, Foot Protection, Protective Clothing & Gloves
Reference www.osha.gov
29 CFR 1910.132 - General Requirements (PPE)
29 CFR 1910.133 - Eye (PPE)
29 CFR 1910.134 - Respiratory (PPE)
29 CFR 1910.136 - Feet (PPE)
29 CFR 1910.138 - Protective Clothing & Gloves (PPE)
29 CFR 1926.101 - Hearing (PPE)
2 - Inspect Remote Control Handles & Control Hose/Cord
Every 8 Hours Of Use
3 - Inspect Blast Hose, Couplings & Gaskets
Every 8 Hours Of Use
4 - Inspect Blasting Nozzle
Every 8 Hours Of Use
5 - Inspect Air Hose, Couplings & Gaskets
Every 8 Hours Of Use
6 - Inspect & Clean Blow-Down Muffler (If Equipped)
Every 40 Hours Of Use
7 - Lubricate Inlet Valve
Every 40 Hours Of Use
8 - Inspect Pop-Up & Pop-Up Gasket
Every 200 Hours Of Use
9 - Service Inlet Valve
Every 200 Hours Of Use
10 - Service Diaphragm Outlet Valve
Every 200 Hours Of Use
11 - Service Metering Valve
Every 600 Hours Of Use
12 - Service Electric Control Valve (If Equipped)
Every 600 Hours Of Use
Maintenance Schedule