Indoor Unit Installation Location Selection
Follow the below best practices for selecting an optimal space for installation the indoor unit:
•
DO NOT
install the unit on a wall that is subject to vibrations.
•
DO NOT
install the system near sources of heat, steam, or flammable gases.
•
DO NOT
install the indoor unit in a location that is exposed to direct sunlight.
•
DO
ensure that the inlet and outlet vents are not obstructed. The system should be able to
output air all over the entire room.
•
DO
minimize the distance between the indoor and outdoor unit and install the unit in a
place where connecting the indoor and outdoor unit will be as simple as possible.
•
DO
install the unit on a strong wall and where it is easy to drain the condensate water.
•
DO
install the unit in a location where it will be easy to service the machine and perform
any necessary maintenance.
•
DO
obey the following tolerances depicted in the illustration below:
Page 22
6
Indoor Unit Installation Instructions
Indoor Unit Installation
10-15 cm (4-6in)
or more
2.0 m (80 in) or more
10-15 cm (4-6 in)
or more
10-15 cm (4-6 in) or more