temp. During the 7 minutes, the frequency
limitation is active.
7 minutes later, the compressor running
frequency will be controlled as below:
+5.0
+4.5
+3.5
+3.0
+2.5
+2.0
+1.5
+1.0
H
G
H
F
E
D
C
B
A
+0.5
While the zones of A,B,C... are corresponding
to different compressor running frequency.
ΔT=0
℃
as default.
Note:
When T1-Ts keeps in the same temp. zone for
3 minutes, the compressor will run as per the
below rules:
A~E: Increase the frequency to the higher level
until reaching F10.
F: Keep the current frequency.
G: Decrease the frequency to the lower level
until reaching F1.
H: Run at F1 for 1h.(if T1-Ts-ΔT >6
℃
, the
compressor will stop)
Meanwhile, the compressor running frequency
is limited by the current.
I3HEAT
I2HEAT
I1HEAT
Off
Decrease
Hold
Resume
I3HEAT, I2HEAT,I1HEAT mean different
running current value.
Off: Compressor stops.
Decrease: Decrease the running frequency to
the lower level.
Hold: Keep the current frequency.
Resume: No limitation for frequency.
Note:
When AC is in “hold” zone for 3 minutes, the
compressor frequency will rise to the higher
level. (The frequency will increase twice at
most)
8.4.3.2 Outdoor fan running rules
17
15
Low
High
Содержание WAE009AMFI15RL
Страница 7: ...5 2 2 Part names of Indoor Outdoor units ...
Страница 16: ...14 5 Wiring Diagram 5 1 Indoor Unit 9000 BTU 230V Heat Pump 12000 BTU 230V Cool Only 12000 BTU 230V Heat Pump ...
Страница 18: ...16 24000 BTU 230V Cool Only 24000 BTU 230V Heat Pump ...
Страница 20: ...18 18000 BTU 230V Cool Only 18000 BTU 230V Heat Pump 24000 BTU 230V Cool Only 24000 BTU 230V Heat Pump ...
Страница 22: ...20 For 18000 BTU 230V Cool Only 18000 BTU 230V Heat Pump For 24000 BTU 230V Cool Only 24000 BTU 230V Heat Pump ...
Страница 53: ...51 P U P V ...
Страница 54: ...52 P W P N ...