The System Setup menu
08
44
En
Note that changing the room (for example, moving
furniture or paintings) will affect the calibration results.
In such cases, you should recalibrate your system.
Using Professional Acoustic Calibration EQ
1
Select ‘EQ Professional’ then press ENTER.
2
Select an option and press ENTER.
•
Reverb Measurement
– Use this to measure the
reverb characteristics of your room.
•
Reverb View
– You can check the reverb
measurements made for specified frequency ranges
in each channel.
•
Advanced EQ Setup
– Use this to select the time
period that will be used for frequency adjustment and
calibration, based on the reverb measurement of
your listening area. Note that customizing system
calibration using this setup will alter the settings you
made in
Automatically setting up for surround sound
(Auto MCACC)
on page 8 or
Automatic MCACC
(Expert)
on page 37 and is not necessary if you’re
satisfied with these settings.
3
If you selected ‘Reverb Measurement’, select EQ
ON or OFF and then OK.
The following options determine how the reverb
characteristics of your listening area are displayed in
Reverb View
:
•
EQ OFF
– You will see the reverb characteristics of
your listening area
without
the equalization
performed by this receiver (before calibration).
•
EQ ON
– You will see the reverb characteristics of
your listening area
with
the equalization performed
by this receiver (after calibration).
1
Note that the EQ
response may not appear entirely flat due to
adjustments necessary for your listening area.
When the reverb measurement is finished, you can select
Reverb View
to see the results on-screen.
4
If you selected ‘Reverb View’, you can check the
reverb characteristics for each channel. Press
RETURN when you’re done.
This appears according to the setting you chose in
Reverb Measurement
(step 3 above). Use the
/
buttons to select the channel and the frequency you want
to check. Use the
/
buttons to go back and forth
between the two. Note that the markers on the vertical
axis indicate decibels in 2 dB steps.
5
If you selected ‘Advanced EQ Setup’, input the
time setting you want to use for calibration, then
select ‘Go’. Select ‘Start’ from the next screen.
Based on the reverb measurement above, you can
choose the time period that will be used for the final
frequency adjustment and calibration. Even though you
can make this setting without reverb measurement, it is
best to use the measurement results as a reference for
your time setting. For an optimal system calibration
based on the direct sound coming from the speakers, we
recommend using the
30~50ms
setting.
Use the
/
buttons to select the channel, frequency,
and time setting. Use the
/
buttons to switch
between them.
You can switch between your connected speakers
(excluding the subwoofer), and display the
measurements for the following frequencies: 63 Hz, 125
Hz, 250 Hz, 500 Hz, 1 kHz, 2 kHz, 4 kHz, 8 kHz and 16 kHz.
Select the setting from the following time periods (in
milliseconds):
0~20ms
,
10~30ms
,
20~40ms
,
30~50ms
,
40~60ms
,
50~70ms
and
60~80ms
. This setting will be
applied to all channels during calibration.
When you’re finished, select
OK
. It will take about 1 to 4
minutes for the calibration to finish.
After the Acoustic Calibration Equalization is set, you are
given the option to check the settings on-screen.
Note
1 The calibration corresponding to the currently selected MCACC preset will be used when EQ ON is selected. To use another MCACC preset, exit the
System Setup menu and press
MCACC
to select it before pressing
SETUP
.
3.Manual MCACC
a.Fine Ch Level
b.Fine SP Distance
c.Standing
Wave
d.EQ Adjust
e.EQ Professional
:Return
3e.EQ Professional
1.Reverb Measurement
2.Reverb View
3.Advanced EQ Setup
ENTER:Next :Return
3e1.Reverb Measurement
MCACC: M1.MEMORY 1
Measure with
EQ OFF
Setting Start?
[OK]
:Cancel
3e1.Reverb Measurement
Now Analyzing…
(1/5)
M1. MEMORY 1 EQ:ON
Ambient
Noise
[
OK
]
Microphone
[
]
Speaker
Level
[
]
Delay Check
[ ]
Reverb
[ ]
:Cancel
3e2.Reverb View
M1 : EQ OFF
Ch [
L
]
Fq [ 63Hz
]
:Return
0
80
160ms
dB
3e4. Adv. EQ Setup (1/2)
( Next)
Ch [
L
]
Fq [ 63Hz
]
Tm [60
~
80ms]
0
80
160ms
dB
:Cancel
3e4. Adv. EQ Setup (2/2)
( Back )
EQ Type
[ALL CH ADJUST]
Multi-Point
NO
Setting Start?
[OK]
: Cancel