37
SVM-1000
5
6
7
8
5
6
7
8
A
B
C
D
E
F
Page6 : METER TEST
Mode to check the LED segments of the meters by turning them on one by one
Each time you press the CUE key, the LED segments of the meters for
each channel light one by one.
All segments are dark at the beginning. When you press the key again
after your 15th press of the key (when the top LED is lit), all segments
will go dark again, permitting the test to be repeated from the beginning.
CH1 CUE
: CH1 level meter
CH2 CUE
: CH2 level meter
CH3 CUE
: CH3 level meter
CH4 CUE
: CH4 level meter
MASTER CUE
: MASTR L CH level meter
EFFECT CUE
: MASTR R CH level meter
Check the responses of the touch panels.
Press the touch-panel check buttons. Proper responses of the buttons
mean that the touch panels function properly.
If there is any misalignment, activate Service mode to re-calibrate the
panels.
Page7 : TOUCH PANEL TEST
Mode to indicate the coordinates on the touch panels being touched
While you are touching the lower (bottom) touch panel,
the corresponding coordinates on the panel are displayed.
Touch-panel check buttons
When you touch them correctly, the color of each touched
button changes between blue and red.
While you are touching the upper (top) touch panel,
the corresponding coordinates on the panel are displayed.
CH1
CUE
CH2
CUE
EFFECT
CUE
CH3
CUE
CH4
CUE
MASTER
CUE
Содержание SVM 1000 - Audio/Video Mixer
Страница 9: ...9 SVM 1000 5 6 7 8 5 6 7 8 A B C D E F 2 3 PANEL FACILITIES ...
Страница 10: ...10 SVM 1000 1 2 3 4 A B C D E F 1 2 3 4 ...
Страница 11: ...11 SVM 1000 5 6 7 8 5 6 7 8 A B C D E F ...
Страница 12: ...12 SVM 1000 1 2 3 4 A B C D E F 1 2 3 4 ...
Страница 52: ...52 SVM 1000 1 2 3 4 A B C D E F 1 2 3 4 AUD1 Assy AUD2 Assy Diagnosis ...
Страница 167: ...167 SVM 1000 5 6 7 8 5 6 7 8 A B C D E F ...
Страница 169: ...169 SVM 1000 5 6 7 8 5 6 7 8 A B C D E F CN9152 AD CN9151 AD CN201 CN202 ...
Страница 185: ...185 SVM 1000 5 6 7 8 5 6 7 8 A B C D E F ...