57
SC-09TX
5
6
7
8
5
6
7
8
A
B
C
D
E
F
While the bus is resetting
Flashes for at least 2 sec.
Flashes for at least 2 sec.
Flashes for at least 2 sec.
Flashes for at least 2 sec.
Flashes for at least 2 sec.
Flashes for at least 2 sec.
Flashes for at least 2 sec.
Lights at least 2 sec.
Lights at least 2 sec.
Lights at least 2 sec.
Lights at least 2 sec.
Lights at least 2 sec.
When the i.Link bus is busy
When no signal can be received from the assigned equipment
When transmission of data is unstable
When a link cannot be established, as the assigned
equipment does not support AV/C protocol
When the database could not be cleared properly
When the i.Link connection is looped
When flow control is turned ON
When flow control is turned OFF
During writing of Config ROM data
When a MODEL ID error is generated
LINK CHECK
BUS FULL
NO SIGNAL
CANNOT LINK1
CANNOT LINK2
DB ERROR
LOOP CONNECT
PQLS ON
PQLS OFF
WRITING CONFIG
MODEL ID ERROR
CONFIG ERROR
When a Config ROM data error is generated
Error Indications Upon Detection of Abnormalities in the Amp/Communication
Systems (3)
[Purpose]
Errors upon detection of abnormalities in the i.Link system are indicated.
[Error indications]
OSD
Status
Timing (sec.)
[Descriptions]
LINK CHECK
: New equipment has been added in the i.Link path, or equipment has been removed from the
i.Link path.
BUS FULL
: As the i.Link bus is busy, this unit cannot receive a signal via the i.Link.
NO SIGNAL
: Although the assigned equipment supports AV/C protocols, an output plug is not connected.
CANNOT LINK1
: Data transmission between the assigned equipment and this unit becomes unstable.
Communication (Mercury) error.
CANNOT LINK2
: The i.Link could not be established, as the assigned equipment does not support AV/C protocols.
: The database could not be cleared properly, even though the corresponding two keys were
simultaneously pressed.
: The i.Link connection is looped.
: As one player is connected to this unit, flow control becomes available.
This indication is displayed only when the number of players connected to this unit goes from
multiple to single.
: As multiple players are connected to this unit, flow control becomes unavailable.
This indication is displayed only when the number of players connected to this unit goes from
single to multiple.
WRITING CONFIG : The Config-ROM data writing starts when the unit is turned on for the first time after a new host
board has been installed in this unit.
MODEL ID ERROR : The model ID stored in the flash memory on the host board and that stored in this unit are different.
CONFIG ERROR
: This error is generated when the unit is turned off while the Config ROM data are being written
to the flash memory.