62
PDU-50WX2
GS1:
Output data such as version information, hour meter and pulse meter
• Output it according to transmission order and size of the table below.
GS2:
Output data of power down, temperature and dew drop information
• Output it according to transmission order and size of the table below.
Order
Data Contents
Size
Remarks
1
Display information
3 byte
See below
2
Module microcomputer model number
4 byte
F691
3
Module microcomputer version
3 byte
4
Panel microcomputer version
3 byte
5
Panel /FLASH ROM version
3 byte
6
Hour meter (hour)
5 byte
Unit: H (time)
7
Pulse meter
7 byte
Unit: 0.01G (10,000,000)
Data
Model
MX5
PDP-503MX
MX4
PDP-433MX
MD5
Module 50 inches
MD4
Module 43 inches
HD5
PDP-503HD
HD4
PDP-433HD
Order
Data Contents
Size
Remarks
1
AC information
1 byte
Always 0 (not used)
2
Service parts distinction
1 byte
0: MX adjustment completion ASSY
1: Module adjustment completion ASSY (Service Assy)
Module ASSY is always 1
3
Hour meter (hour, minute)
7 byte
*****H**M
4
Power down information
2 byte
1st/2nd
5
Temperature information
3 byte
8 bit
6
Dew drop information
1 byte
1: Dew drop NG
7
Panel microcomputer communication
1 byte
1: Communication NG
8
DIGITAL EEPROM communication
1 byte
1: Communication NG
9
DIGITAL EXPANDER communication
1 byte
1: Communication NG
Display Information
Data
Power Down Point
0
Nothing
1
Y-DRIVE
2
Y-DC/DC CONVERTER
3
X-DC/DC CONVERTER
4
X-DRIVE
5
Power supply
6
ADDRESS junction
7
ADDRESS resonance
8
DC/DC CONVERTER (DIGITAL)
(Note) Refer to the following table about contents of PD information