PDR-F10
6.6 SERVO ADJUSTMENT
6.6.1 Preparations
1. Enter the TEST mode.
2. Press the DIG/ ANA key so that " " appears on the FL display.
3. Press the CLEAR key more than three seconds to initialize it.
4. Press the
3
x3 key to perform the average process.
\
" " disappears on the FL display when completed.
MANUAL ADJUSTMENT
[Procedure]
1. Monitor the FOCUS ERROR waveform with VC.
2. Adjust the SCAN key so that FE offset becomes zero.
3. Press the SEARCH key to register the adjustment.
6.6.2 Focus Offset Adjustment
0 mV
±
30 mV
Optimizing DC offset voltage of focus-error amplifier.
Focal-in does not function, or bad RF wave shape.
CN102-pin 8 (Focus err)
Test Point
Adjustment Value
Purpose
Symptom when Out of Adjustment
Adjustment method
FL Indication
CN102
FE
VC
8
6
10: 1 prove
Oscilloscope
[Procedure]
1. Press the CX key and shift to the SRFO Offset Adjustment.
2. Monitor the RFDC waveform with VC.
2. Adjust the SCAN key so that RFDC offset becomes zero.
3. Press the SEARCH key to register the adjustment.
6.6.3 SRFO Offset Adjustment
0 mV
±
30 mV
CN102-pin 2 (RF)
Test Point
Adjustment Value
Optimizing DC offset voltage of RFDC output circuit when recording.
Recording does not function.
Purpose
Symptom when Out of Adjustment
Adjustment method
FL Indication
CN102
RF
VC
2
6
10: 1 prove
Oscilloscope
Notes : Each test mode key uses remote control for service.
Содержание PDR-F10
Страница 7: ...7 PDR F10 ...
Страница 25: ...PDR F10 25 A B C D 5 6 7 8 5 6 7 8 A 1 5 CN302 NORMAL MECHA ADJ SYSTEM CONTROL 1 2 C ...
Страница 69: ...69 PDR F10 Pin Function 2 5 ...
Страница 70: ...70 PDR F10 Pin Function 3 5 ...
Страница 71: ...71 PDR F10 Pin Function 4 5 ...
Страница 72: ...72 PDR F10 Pin Function 5 5 ...
Страница 76: ...76 PDR F10 AK8567 CD R CORE ASSY IC101 RF Processor Pin Function 1 2 ...
Страница 77: ...77 PDR F10 Pin Function 2 2 ...