(5) Vertical Line
(5-1)
Symptom:
1 vertical line (Open mode)
(5-2)
Symptom:
2 vertical lines (Short mode)
(5-3)
Symptom:
Vertical Line Block
Red 1 Line Open Mode
Shortage between Red and Blue
Cause/Countermeasure:
1
Open or contact failure of Data flexible cable
⇒
Clean, Reconnect or exchange connector.
2
Failure in Data IC
⇒
Exchange PDP.
3
Failure in panel
⇒
Exchange PDP.
Note:
Typical Symptom are only shown. Another Symptom might appear.
All Red Pattern
⇒
Black 1 Line
All Red Pattern
⇒
Blue 1 Line
All Green Pattern
⇒
Normal
All Blue Pattern
⇒
Red 1 Line
All Black Pattern
⇒
Normal
All Green Pattern
⇒
Red 1 Line
All Blue Pattern
⇒
Red 1 Line
All Black Pattern
⇒
Normal
Cause/Countermeasure:
1
Failure in Data IC
⇒
Exchange PDP.
2
Failure in panel
⇒
Exchange PDP.
Cause/Countermeasure:
1
Open or contact failure of Data flexible cable
⇒
Clean,
Reconnect or exchange connector.
2
Failure in Data IC
⇒
Exchange PDP.
Cause/Countermeasure:
1
Open or contact failure of connector between Data
Relay Board and Digital or High Voltage board
⇒
Clean, Reconnect or exchange connector.
2
Open or contact failure of multiple Data flexible cable
⇒
Clean, Reconnect or exchange connector.
3
Failure in Data Relay Board
⇒
Exchange Data Relay
Board.
4
Failure in multiple Data IC
⇒
Exchange PDP.
Содержание PDP-505MX
Страница 7: ...PDP 505MX 7 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 21: ...PDP 505MX 21 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 46: ...PDP 505MX 46 1 2 3 4 1 2 3 4 C D F A B E Sensor Board IR Board Power Switch Board ...
Страница 47: ...PDP 505MX 47 5 6 7 8 5 6 7 8 C D F A B E Button ...
Страница 48: ...PDP 505MX 48 1 2 3 4 1 2 3 4 C D F A B E Audio Board ...
Страница 49: ...PDP 505MX 49 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 50: ...PDP 505MX 50 1 2 3 4 1 2 3 4 C D F A B E PS250 PWR 500W ...
Страница 51: ...PDP 505MX 51 5 6 7 8 5 6 7 8 C D F A B E ...