61
PDP-503PE, PDP-503PU
Display example of the twelfth page
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
ABL V
2
1 / 1 3
PUT1 No S I G
N
I
I DE
1 1 8
6 0 PC
O
ABL V I DE
1 2 2
5 0
O
VOF
ADJ
1 3 1
S
VSU
ADJ
1 2 8
S
XSU
ADJ
0 8
SB
XSU
ADJ
0 8
SG
YSU
ADJ
0 8
SB
YSU
ADJ
0 8
SG
No.
Item
Adjustable Range
Shipping Setting
Storage Place
1
Electric power setting at the PC, VIDEO 60Hz
0 to 255
Factory adjustment value
PDP
2
Electric power setting at VIDEO 50Hz
0 to 255
Factory adjustment value
PDP
3
VOFS voltage setting
0 to 255
Factory adjustment value
PDP
4
VSUS voltage setting
0 to 255
Factory adjustment value
PDP
5
SUS_B timing setting of X drive
0 to 15
Factory adjustment value
PDP
6
SUS_G timing setting of X drive
0 to 15
Factory adjustment value
PDP
7
SUS_B timing setting of Y drive
0 to 15
Factory adjustment value
PDP
8
SUS_G timing setting of Y drive
0 to 15
Factory adjustment value
PDP
Adjustment item of this page is related in damage of the set when mistakes adjustment. When adjustment is needed, be enough
careful to adjustment.
Caution in the electric power setting (No. 1 and 2) adjustment:
Adjustment value is reflected without relation in input signal during adjustment to the actual PDP.
For example, when operate a adjustment value of [ABL VIDEO 60 PC] during PAL input, switch to the adjustment value operation of [ABL
VIDEO 60 PC] while displaying PAL in the actual PDP. This is temporary.
After adjustment, it becomes the [ABL VIDEO 50] operation in the PAL input after restarted in the normal mode. It becomes an operation of the
[ABL VIDEO 60PC] adjustment value after adjustment in the NTSC input.
∗
: Be careful so that there is the case that page constitution is different.