4
PDP-503PE, PDP-503PU
7
Charged Section
The places where the commercial AC power is used without
passing through the power supply transformer.
If the places are touched, there is a risk of electric shock. In addition,
the measuring equipment can be damaged if it is connected to the
GND of the charged section and the GND of the non-charged
section while connecting the set directly to the commercial AC
power supply. Therefore, be sure to connect the set via an insulated
transformer and supply the current.
1. AC Power Cord
2. AC Inlet with Filter
3. Power Switch (S1)
4. Fuse (In the SW POWER SUPPLY Module)
5. STB Transformer and Converter Transformer
(In the SW POWER SUPPLY Module)
6. Other primary side of the SW POWER SUPPLY Module
CHARGED SECTION AND HIGH VOLTAGE GENERATING POINT
7
High Voltage Generating Point
The places where voltage is 100V or more except for the charged
places described above. If the places are touched, there is a risk of
electric shock.
1. SW POWER SUPPLY Module ...................................... (225V)
2. X DRIVE Assy .............................................. (–300V to 225V)
3. Y DRIVE Assy ............................................................... (355V)
4. SCAN (A) Assy .............................................................. (355V)
5. SCAN (B) Assy ............................................................... (355V)
6. X CONNECTOR (A) Assy ........................... (–300V to 225V)
7. X CONNECTOR (B) Assy ............................ (–300V to 225V)
AC Inlet with Filter
Power Cord
Power Switch
(S1)
Fig.1 Charged Section and High Voltage Generating Point (Rear View)
: Part is the High Voltage Generating Points
other than the Charged Section.
: Part is Charged Section.
X DRIVE
Assy
X CONNECTOR (B)
Assy
Y DRIVE
Assy
SCAN (A)
Assy
SCAN (B)
Assy
∗
Remove the IF Earth Metal (No.14 on the page 25)
beforehand when inclines the power supply unit
as the right figure.
X CONNECTOR (A)
Assy
SW POWER SUPPLY
Module
Top
Front