PDP-5000EX
176
1
2
3
4
1
2
3
4
C
D
F
A
B
E
No.
Mark
Pin Name
I/O Active
Pin Function
51
P41/A17
H_DET_B
I
L
H existence distinction
52
P40/A16
AL_SEL
O
H
UART switch (For IC3201 selection)
53
P37/A15
RST_SQ
O
L
SQ IC (IC3201 and IC3301) forced reset
54
P36/A14
CE_SQ
O
L
Enable for SQ IC (IC3201 and IC3301) communication
55
P35/A13
BUSY_SQ
I
H
Busy for SQ IC (IC3201 and IC3301) communication
56
P34/A12
−
O
57
P33/A11
−
O
58
P32/A10
AR_SEL
O
H
UART switch (For IC3301 selection)
59
P31/A9
WE_SQ
O
H
Switching signal of Flash rewriting path for SQ IC
60
VCC2
VCC2
−
STB 3.3 V
61
P30/A8(/-/D7)
PD_TRG
I
L
EXT_PD confirmation
62
VSS
GND
−
GND
63
P27/AN27/A7(/D7/D6)
SCAN_PD
I
H
SCAN decrease voltage PD
64
P26/AN26/A6(/D6/D5)
YDRV_PD
I
H
Y drive PD
65
P25/AN25/A5(/D5/D4)
YSUS_PD
I
H
Y-SUS PD
66
P24/AN24/A4(/D4/D3)
YDCDC_PD
I
H
DCDC converter PD of Y drive
67
P23/AN23/A3(/D3/D2)
SCN5V_PD
I
H
SCAN5V decrease voltage PD
68
P22/AN22/A2(/D2/D1)
XSUS_PD
I
H
X-SUS PD
69
P21/AN21/A1(/D1/D0)
XDCDC_PD
I
H
DCDC converter PD of X drive
70
P20/AN20/A0(/D0/-)
XDRV_PD
I
H
X drive PD
71
P17/D15/*INT5
−
I
72
P16/D14/*INT4
−
I
73
P15/D13/*INT3
AC_DET
I
L
AC power monitor
74
P14/D12
PBF
I
Panel distinction of High-efficiency/Conventional (FHD: L)
75
P13/D11
−
I
76
P12/D10
−
I
77
P11/D9
−
I
78
P10/D8
−
I
79
P07/AN17/D7
ADRS_PD
I
H
Address PD
80
P06/AN16/D6
−
I
81
P05/AN15/D5
−
I
82
P04/AN14/D4
SS_MODE
O
L
SSCG operation L: SSCG ON, H: SSCG OFF
83
P03/AN13/D3
R_SQ_NON
I
H
Drive stop detection of SQ IC (IC3301)
84
P02/AN12/D2
DDC_PD
I
H
DCDC converter PD
85
P01/AN11/D1
PS_PD
I
H
PD in the POWER SUPPLY Unit
86
P00/AN10/D0
L_SQ_NON
I
H
Drive stop detection of SQ IC (IC3201)
87
P107/AN07/*KI3
OFF_DET_AR
O
L
Drive stop output to SQ IC (IC3301)
88
P106/AN06/*KI2
DL_FIN_AR
I
H
Rewriting completion signal of SQ IC (IC3301)
89
P105/AN05/*KI1
OFF_DET_AL
O
L
Drive stop output to SQ IC (IC3201)
90
P104/AN04/*KI0
DL_FIN_AL
I
H
Rewriting completion signal of SQ IC (IC3201)
91
P103/AN03
−
O
92
P102/AN02
TEMP1
I
−
Panel temperature sensor input
93
P101/AN01
MODE
I
−
Assy operation mode setting
94
AVSS
GND
I
GND
95
P100/AN00
PSIZE
I
L
G7 size distinction (FHD: L)
96
VREF
VREF
I
−
Reference voltage for A/D input
97
AVCC
AVCC
I
STB 3.3 V
98
P97/*ADTRG/SIN4
RXD_AR
I
L
Serial communication with SQ IC (IC3301) Data reception
99
P96/ANEX1/SOUT4
−
O
100 P95/ANEX0/CLK4
CLK_SQ
I
Serial communication with SQ IC (IC3201 and IC3301) Clock input
Содержание PDP-5000EX
Страница 38: ...PDP 5000EX 38 1 2 3 4 1 2 3 4 C D F A B E 4 BLOCK DIAGRAM AND SCHEMATIC DIAGRAM 4 1 OVERALL WIRING DIAGRAM ...
Страница 41: ...PDP 5000EX 41 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 42: ...PDP 5000EX 42 1 2 3 4 1 2 3 4 C D F A B E 4 2 2 MULTI BASE SECTION BLOCK DIAGRAM MULTI BASE SECTION ...
Страница 43: ...PDP 5000EX 43 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 44: ...PDP 5000EX 44 1 2 3 4 1 2 3 4 C D F A B E 4 3 FHD MAIN ASSY FHD MAIN ASSY ...
Страница 45: ...PDP 5000EX 45 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 46: ...PDP 5000EX 46 1 2 3 4 1 2 3 4 C D F A B E 4 4 50FHD X DRIVE ASSY 50FHD X DRIVE ASSY ...
Страница 47: ...PDP 5000EX 47 5 6 7 8 5 6 7 8 C D F A B E from Power supply X Drive power supply map ...
Страница 48: ...PDP 5000EX 48 1 2 3 4 1 2 3 4 C D F A B E 4 5 50FHD Y DRIVE ASSY 50FHD Y DRIVE ASSY ...
Страница 51: ...PDP 5000EX 51 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 54: ...PDP 5000EX 54 1 2 3 4 1 2 3 4 C D F A B E 4 9 POWER SUPPLY UNIT POWER SUPPLY UNIT ...
Страница 167: ...PDP 5000EX 167 5 6 7 8 5 6 7 8 C D F A B E 10 3 LED INFORMATION LED Pattern State LED Pattern ...