7.3 HOW TO CLEAR HISTORY DATA
Clearance of various logs after the Assys are replaced
(1) Clearance of logs, using the RS-232C commands
Besides adjustment data, data on accumulated power-on time and logs on defective parts of the product are backed up. Some
of those data must be cleared after the Assys are replaced for service.
Notes: •
As the pulse-meter count is used for each correction function, it must be cleared when an Assy relevant to
correction functions is replaced.
•
When clearing logs, using the RS-232C commands, first enter Factory mode (by issuing FAY or PFY), then issue
the corresponding command.
Item
Content
When the Panel
is replaced
When the POWER
SUPPLY Unit
is replaced
When the Other
Assy
is replaced
RS-232C
Commands
Hour-meter
Accumulated power-on time
Must be cleared
No need to be
cleared
No need to be
cleared
CHM
Pulse-meter
Accumulated number of pulses
emitted
Must be cleared
(mandatory)
No need to be
cleared
No need to be
cleared
CPM
Shutdown history
Cause of an SD and hour-meter
count
Must be cleared
No need to be
cleared
No need to be
cleared
CSD
Power-down history
Cause of an PD and hour-meter
count
Must be cleared
No need to be
cleared
No need to be
cleared
CPD
Power-on counter
Relay-on count
No need to be
cleared
Must be cleared
(mandatory)
No need to be
cleared
CPC
MAX TEMP
Historical max. temperature
Must be cleared
Must be cleared
Must be cleared