Fig.2 High Voltage Generating Point (Rear view)
High Voltage Generating Point
42 SCAN B Assy
Conductive
plate X
42 Y DRIVE Assy
42 X DRIVE Assy
SUS CLAMP 1 Assy
SUS
CLAMP 2 Assy
Power Supply Unit
42 SCAN A Assy
Charged Section
The places where the commercial AC power is used without
passing through the power supply transformer.
If the places are touched, there is a risk of electric shock. In
addition, the measuring equipment can be damaged if it is
connected to the GND of the charged section and the GND of the
non-charged section while connecting the set directly to the
commercial AC power supply. Therefore, be sure to connect the
set via an insulated transformer and supply the current.
1. Power Cord
2. SUB EMI Filter Assy
3. SUB Power Switch (S1) Assy
4. Fuse (In the POWER SUPPLY Unit)
5. STB Transformer and Converter Transformer
(In the POWER SUPPLY Unit)
6. Other primary side of the POWER SUPPLY Unit
: Part is the High Voltage Generating Points
other than the Charged Section.
: Part is Charged Section.
• PDP-4216HD
The places where voltage is 100 V or more except for the charged
places described above. If the places are touched, there is a risk of
electric shock.
The VSUS voltage remains for several minutes after the power to
the unit is turned off. These places must not be touched until
about 10 minutes after the power is turned off, or it is confirmed
with a tester that there is no residual VSUS voltage.
If the procedures described in “10.3 POWER ON/OFF FUNC-
-TION FOR THE LARGE-SIGNAL SYSTEM” are performed
before the power is turned off, the voltage will be discharged in
about 30 seconds.
POWER SUPPLY UNIT ....................................................(205 V)
42 X DRIVE Assy.............................................................. (500 V)
42 Y DRIVE Assy............................................................... (500 V)
42 SCAN A Assy................................................................ (500 V)
42 SCAN B Assy................................................................ (500 V)
SUS CLAMP 1 Assy.......................................... (–180 V to 205 V)
SUS CLAMP 2 Assy.......................................... (–180 V to 205 V)
SUB EMI
FILTER Assy
SUB POWER
SWITCH Assy
www. xiaoyu163. com
QQ 376315150
9
9
2
8
9
4
2
9
8
TEL 13942296513
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299