PDP-5016HD
187
5
7
8
5
6
7
8
C
D
F
A
B
E
9.3.2 QS2
Data Arrangement
Data
Length
Output Example
ECO
3 Byte
QS2
1
Notification of mode shifting to STB
1 Byte
1
2
Flag for adjustment of the main unit
1 Byte
0
3
Flag for adjustment-data backup
1 Byte
0
4
"1st PD" data
1 Byte
0
5
"2nd PD" data
1 Byte
0
6
Still picture detection
1 Byte
0
7
Reserved
2 Byte
∗∗
8
Temperature data (TEMP 1)
3 Byte
128 (*1)
9
SD main data
1 Byte
0
10
SD sub data
1 Byte
0
11
Operation status induced by SD
1 Byte
0
12
Data from the hour meter
8 Byte
00000259 (*2)
13
MASK indication
1 Byte
0
CS
2 Byte
4A
1: Notification of mode
shifting to Standby
0
Entering Standby
mode failed
Entering Standby
mode succeeded
3: Adjustment-data
backup
0
With backup data
1
No data (default)
6: Still picture
detection
0
Normal screen
1
Still picture
4, 5: PD data
0
No PD data
1
Not used
2
POWER
3
SCAN
4
SCN-5V
5
Y-DRV
6
Y-DCDC
7
Y-SUS
8
ADRS
9
X-DRV
A
X-DCDC
10-1: SD-Sub (SQ-IC)
0
No SD-Sub data
1
Communication error
2
Drive stop
3
BUSY
6
Version mismatching
B
X-SUS
C
Not used
D
Not used
E
Not used
F
UNKNOWN
9: SD main data
0
No SD
1
SQ-IC
2
MDU-IIC
3
RST2
4
TEMP
11: Operation status
induced by SD
0
Normal
1
Relay-off completed
2
During warning
indication
13: MASK indication
0
MASK-OFF
1
MASK-ON
Command
Format
Effective Operation
Modes
Function
Remarks
[QS2]
All operations
To acquire data on operations of the panel Return data: 3 (ECO)+23(DATA)+2(CS)= 28 Byte
7
Acquisition of panel operation data • • • [QS2]
The command QS2 is for acquiring data on the panel's operational information.
Note :
(*1) The unit scale is centigrade. The data is A/D value from the
thermal sensor.
(*2) "00000259" of "Data from the hour meter" means
2 hours 59 minuts.
10-2: SD-Sub (IIC)
0
No SD-Sub data
1
EEPROM
2
BACKUP
3
DAC
10-3: SD-Sub (TEMP)
0
No SD-Sub data
1
TEMP1
2
Reserved