103
PRO-141FD
5
6
7
8
5
6
7
8
A
B
C
D
E
F
5.9 DETAILS OF RS-232C AND IP COMMANDS
[1] QS2 (PANEL OPERATION DATA)
Data Arrangement
Data
Length
Output Example
ECO
3 byte
QS2
1
Notify of the standby operation transition
1 byte
1
2
Adjustment flag of the main unit
1 byte
0
3
Adjustment-data backup flag
1 byte
0
4
"1st PD" data
1 byte
0
5
"2nd PD" data
1 byte
0
0
6
Color sensor data
1 byte
∗∗
∗∗∗∗
∗∗∗
7
Reserved
2 byte
8
Temperature data (TEMP 1)
3 byte
128
9
SD data
1 byte
0
10
SD subcategory data
1 byte
0
11
Operation status induced by SD
1 byte
0
12
Reserved
3 byte
00000259
13
HOUR METER
8 byte
0
0
0
0
14
MASK indication
1 byte
0
4A
15
Still picture detection
1 byte
16
SCAN protection detection
1 byte
17
Panel crack detection
1 byte
18
19
Address emergency detection
1 byte
Reserved
4 byte
CS
2 Byte
2 byte
1: Power supply status
0
Shifting to Passive
Standby is not
possible.
P
During power ON
1
Shifting to Passive
Standby is possible.
2: Adjustment flag of
the main unit
0
Adjustment completed
1
Adjustment not
completed
3: Adjustment-data
backup
flag
0
Adjustment completed
1
Adjustment not completed
4, 5: PD data
0
No PD data
2
POWER
3
SCAN
4
SCN-5V
6
Y-DCDC
7
Y-SUS
8
ADRS
A
X-DCDC
10-1: SD subcategory (SQ_LSI)
0
No SD-Sub data
1
Communication error
2
Drive stop
3
BUSY
4
Version mismatching (H/S)
B
X-SUS
C
DIG-DCDC
F
UNKNOWN
9: SD data
0
No SD
1
SQ_LSI
2
MDU-DEVICE
3
RST2
4
Panel temperature
11: Operation status
induced by SD
0
Normal
1
Relay-off completed
2
During warning
indication
14: MASK indication
0
MASK-OFF
1
MASK-ON
15 to 18: Detection of Each Protection function
0
Normal operation
1
At detection of protection operation
Command
Format
Effective Operation
Modes
Function
Remarks
[QS2]
Every Time
Output of status
Return data: 3 (ECO) + 34 (DATA) + 2 (CS) = 39 Byte
The command QS2 is for acquiring data on the panel's operational information.
10-2: SD subcategory (MD-DEVICE)
0
No SD-Sub data
1
EEPROM
2
BACKUP
3
DAC
6: Color sensor data
-
Function OFF (including standby)
0
Normal
1
Hardware connection is not completed
2
Data mismatching
10-3: SD subcategory
(Panel temperature)
0
No SD-Sub data
1
Panel high temperature
2
Panel low temperature
5
Version mismatching (H/M)
6
Version mismatching (H/I)
Содержание Kuro Elite PRO-141FD
Страница 10: ...10 PRO 141FD 1 2 3 4 A B C D E F 1 2 3 4 2 2 SPECIFICATIONS PRO 141FD KU CBXC ...
Страница 11: ...11 PRO 141FD 5 6 7 8 5 6 7 8 A B C D E F KRP 600M KUCXC ...
Страница 12: ...12 PRO 141FD 1 2 3 4 A B C D E F 1 2 3 4 KRP 600M YVPSLFTD TYVXK5 ...
Страница 13: ...13 PRO 141FD 5 6 7 8 5 6 7 8 A B C D E F 2 3 PANEL FACILITIES For PRO 141FD ...
Страница 14: ...14 PRO 141FD 1 2 3 4 A B C D E F 1 2 3 4 Front Section for KRP 600M ...
Страница 15: ...15 PRO 141FD 5 6 7 8 5 6 7 8 A B C D E F Rear Section for KRP 600M ...
Страница 16: ...16 PRO 141FD 1 2 3 4 A B C D E F 1 2 3 4 Remote Control Unit ...
Страница 17: ...17 PRO 141FD 5 6 7 8 5 6 7 8 A B C D E F ...
Страница 22: ...22 PRO 141FD 1 2 3 4 A B C D E F 1 2 3 4 4 BLOCK DIAGRAM 4 1 OVERALL WIRING DIAGRAM 1 2 ...
Страница 24: ...24 PRO 141FD 1 2 3 4 A B C D E F 1 2 3 4 4 2 OVERALL WIRING DIAGRAM 2 2 ...
Страница 25: ...25 PRO 141FD 5 6 7 8 5 6 7 8 A B C D E F OVERALL DIAGRAM PRO 141FD KRP 600M ...
Страница 37: ...37 PRO 141FD 5 6 7 8 5 6 7 8 A B C D E F ...
Страница 43: ...43 PRO 141FD 5 6 7 8 5 6 7 8 A B C D E F ...
Страница 73: ...73 PRO 141FD 5 6 7 8 5 6 7 8 A B C D E F ...
Страница 209: ...209 PRO 141FD 5 6 7 8 5 6 7 8 A B C D E F ...
Страница 212: ...212 PRO 141FD 1 2 3 4 A B C D E F 1 2 3 4 9 2 PACKING SECTION KRP 600M KUCXC 4 Cable clamps ...
Страница 218: ...218 PRO 141FD 1 2 3 4 A B C D E F 1 2 3 4 9 5 REAR SECTION POWER SUPPLY P8 MAIN CN4104 Refer to 9 6 FRONT SECTION ...
Страница 226: ...226 PRO 141FD 1 2 3 4 A B C D E F 1 2 3 4 9 9 PANEL CHASSIS SECTION ...